{"product_id":"yokogawa-anb10d-415-cu2t-centum-vp-dual-redundant-esb-bus-node-unit","title":"Yokogawa ANB10D-415\/CU2T CENTUM VP Dual-Redundant ESB Bus Node Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-415\/CU2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance expansion node for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system. This unit facilitates mission-critical data exchange between Field Control Units (FCU) and I\/O modules via a dual-redundant Extended Serial Backplane (ESB) bus. Designed for high-availability environments, it maintains continuous process control even during cable damage or power fluctuations. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full manufacturer specifications and long-term field reliability.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe suffix and option codes for the ANB10D series define its specific electrical and communication architecture:\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis node unit provides the physical and logical backbone for up to 8 I\/O modules in a standard cabinet layout.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-Redundant ESB Bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 to 120 V AC (50\/60 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo independent power modules (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated CU2T interface (Requires no external resistors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 I\/O module slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch rack mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintains deterministic data acquisition across the ESB chain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Single Points of Failure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-redundant ESB bus architecture ensures that the control system remains online if one communication line fails. This hardware redundancy prevents costly unplanned shutdowns in continuous process industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined End-of-Line Setup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption integrates the bus terminator directly into the connector unit. This design eliminates the need for separate termination modules, reducing cabinet clutter and simplifying the wiring of the final node in the bus chain.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe chassis design promotes natural convection, allowing the unit to host high-density I\/O modules without exceeding thermal thresholds in standard 19-inch rack enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Power Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual power supply configuration allows maintenance teams to replace a faulty power module while the system remains energized, ensuring zero downtime during hardware servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support 220V AC power input?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The suffix code \"1\" specifically designates a 100-120V AC power requirement. For 220V applications, you must utilize the ANB10D-42x variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this node in a hazardous area?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe suffix \"5\" indicates a basic type without explosion protection. You should install this unit in a non-hazardous (safe) area or within a suitable purged enclosure that meets local safety regulations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the \/CU2T unit necessary for every node?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou specifically require the \/CU2T for the final node in the ESB bus chain to terminate the signal correctly. Intermediate nodes typically use the \/CU2N (without terminator) option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many I\/O modules can this unit hold?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ANB10D-415 provides slots for up to 8 Yokogawa I\/O modules, providing a compact footprint for localized I\/O expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52763034648885,"sku":"ANB10D-415\/CU2T","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ANB10D-427CU2N_1e944008-ea2b-470b-b050-d609f2a04e0b.png?v=1776669773","url":"https:\/\/www.5gplc.com\/products\/yokogawa-anb10d-415-cu2t-centum-vp-dual-redundant-esb-bus-node-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}