{"product_id":"yokogawa-anb10d-415-cu2n-ndel-esb-bus-node-unit-centum-vp","title":"Yokogawa ANB10D-415\/CU2N\/NDEL ESB Bus Node Unit | CENTUM VP","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-415\/CU2N\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-availability expansion interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System. This ESB Bus Node Unit facilitates the connection of local and remote I\/O modules to the Field Control Station (FCS). By utilizing a dual-redundant architecture, it ensures seamless data flow between field instruments and the processor. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring pre-installed software licensing for immediate system expansion.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e(Note: While some technical databases may incorrectly categorize this as an \"Incremental Encoder,\" this hardware is officially a DCS Node Unit used for I\/O signal management.)\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ANB10D-415\/CU2N\/NDEL\u003c\/h3\u003e\n\u003cp\u003eYokogawa employs the following suffix and option logic to define the hardware capabilities of the ANB10D series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant power supply modules included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 - 120 V AC power supply input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type (Non-explosion protection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Unit for ESB Bus (Non-terminator type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/NDEL\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSoftware License for Node Expansion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-415\/CU2N\/NDEL provides robust electrical parameters for heavy industrial operation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant ESB Bus (Extended Serial Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 - 120 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply redundancy and Bus redundancy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes \/NDEL license for additional node addressing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 19-inch rack-mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade components for control room environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-415\/CU2N\/NDEL solves critical connectivity and availability challenges in process automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Single Points of Failure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-redundant power supply configuration ensures that the I\/O node remains active even if one power module fails. The unit draws current from two independent sources, allowing for online replacement of a faulty supply without interrupting the process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePre-Authorized System Scaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elicense removes the administrative hurdle of purchasing expansion keys separately. This allows engineers to increase the node count within the CENTUM VP project software immediately upon hardware installation, significantly accelerating commissioning timelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Bus Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption provides the specialized connector unit required for the ESB bus. This interface simplifies daisy-chaining multiple nodes, ensuring stable, high-speed signal transmission across the system backplane without the risk of loose manual wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Power Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuffix code '1' targets the 100-120V AC standard common in North American and Japanese facilities. The internal power units handle the electrical transients typical of industrial grids, protecting the sensitive FIO modules from voltage spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the \/NDEL software license?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \/NDEL license authorizes the DCS to recognize and communicate with additional node units beyond the base system configuration. Having this pre-installed on the ANB10D-415 simplifies the engineering process during plant expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model include an internal terminator for the ESB bus?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard connector unit. If this node occupies the final position in an ESB bus chain, you must use a connector with a terminator (\/CU2T) or add an external terminator to prevent signal reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an ANB10S with this ANB10D model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the ANB10D (Duplex) provides higher reliability by supporting dual-redundant bus paths. Ensure your Field Control Station (FCS) has the necessary dual-redundant ESB bus ports to utilize the secondary communication channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle the 10 kg weight during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways utilize a standard 19-inch rack with adequate rail support. We recommend installing the unit in the lower or middle section of the cabinet to maintain a low center of gravity for the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52761699287349,"sku":"ANB10D-415\/CU2N\/NDEL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ANB10D-445_18769d0b-da74-46c8-b305-b235acf2e156.jpg?v=1776666470","url":"https:\/\/www.5gplc.com\/products\/yokogawa-anb10d-415-cu2n-ndel-esb-bus-node-unit-centum-vp","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}