{"product_id":"yokogawa-anb10d-415-cu2n-centum-vp-esb-bus-node-unit","title":"Yokogawa ANB10D-415\/CU2N CENTUM VP ESB Bus Node Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-415\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-availability interface for expanding I\/O capacity within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). This ESB Bus Node Unit facilitates high-speed communication between the Field Control Station (FCS) and FIO modules. By supporting dual-redundant ESB bus paths and power modules, this unit maintains continuous process visibility and control. We provide this hardware as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automation architecture meets strict factory specifications for mission-critical reliability.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ANB10D-415\/CU2N\u003c\/h3\u003e\n\u003cp\u003eYokogawa defines the configuration of the ANB10D series through a modular suffix and option system:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuffix 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant power supply configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuffix 2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 - 120 V AC power supply input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSuffix 3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type (Non-explosion protection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Unit for ESB Bus (Includes 2x S9562FA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-415\/CU2N incorporates robust electrical and mechanical parameters to handle high-density I\/O traffic:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Bus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant ESB Bus (Extended Serial Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 - 120 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports dual-path bus and dual-power module hot-swapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch Rack Mounting (Requires 5U space)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Hardware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 pieces of S9562FA Connector Units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Accessories:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eM5 x 4 screws and insulation bushes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 kg (Net)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-415\/CU2N addresses specific industrial installation and uptime challenges:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMitigate Ground Loop Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit includes specialized insulation bushes (accessories). These components isolate the chassis from the rack frame, preventing circulating ground currents from corrupting sensitive analog I\/O signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption provides two S9562FA connector units. These factory-certified connectors ensure a low-impedance path for the 125 Mbps ESB bus, preventing data packet loss in electrically noisy environments near VFDs or high-voltage switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUninterrupted Process Uptime:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-redundant power supply (Suffix -4) configuration allows the node to draw current from independent AC sources. If one power module fails, the secondary module carries the full load instantly, permitting the replacement of the faulty unit without interrupting the control logic or field data flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Cabinet Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for 19-inch rack mounting, the unit utilizes standard M5 screws. This allows engineers to consolidate extensive I\/O points into high-density cabinets, reducing the overall footprint in the control room or Remote Instrument Enclosure (RIE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the \/CU2N option include terminators?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erefers to the standard Connector Unit. If this node sits at the end of an ESB bus chain, you must use a connector unit with a terminator (\/CU2T) or add an external terminator to prevent signal reflection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this unit with 220V AC power?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This specific configuration (Suffix 1) targets 100-120V AC. Applying 220V AC will damage the internal power modules. For 220V applications, you require the ANB10D-425 model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit handle vibration in industrial racks?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10 kg robust chassis and M5 secure mounting system withstand the mechanical vibrations common in process plants. The included insulation bushes also provide a degree of mechanical damping between the unit and the rack frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with the latest CENTUM VP software?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The ANB10D-415 remains a standard component for current CENTUM VP deployments, providing full compatibility with LFS1500 and related control functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52763006730549,"sku":"ANB10D-415\/CU2N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AFV10D-S412111_cf580f9b-d35d-478c-8196-595f067fb4dc.jpg?v=1776668609","url":"https:\/\/www.5gplc.com\/products\/yokogawa-anb10d-415-cu2n-centum-vp-esb-bus-node-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}