{"product_id":"yokogawa-anb10d-410-cu2t-centum-vp-esb-bus-node-unit","title":"Yokogawa ANB10D-410\/CU2T CENTUM VP ESB Bus Node Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ANB10D-410\/CU2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-availability interface for expanding I\/O capacity within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). This ESB Bus Node Unit facilitates high-speed, dual-path communication between the Field Control Station (FCS) and remote FIO modules. By integrating redundant power modules and a specialized terminator interface, the unit ensures deterministic data flow across the system backplane. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing a factory-certified solution for mission-critical process automation.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: ANB10D-410\/CU2T\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes a specific alphanumeric coding system to define the electrical and functional configuration of the node:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant power supply configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 - 120 V AC power supply input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type (Non-explosion protection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/CU2T\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Unit with Integrated Terminator for ESB Bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-410\/CU2T incorporates heavy-duty components designed for continuous industrial operation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant ESB Bus (Extended Serial Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 - 120 V AC (50\/60 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Redundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports two hot-swappable power supply modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated \/CU2T Connector Unit with internal electrical terminator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccommodates Yokogawa FIO (Field Input\/Output) modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch rack-mountable (Occupies 5U of vertical space)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 kg (Net)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LEDs for Power and Communication status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-410\/CU2T addresses specific technical hurdles in DCS deployment and maintenance:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminate Signal Reflections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption provides a built-in terminator within the connector unit. This hardware-level termination prevents signal \"echoes\" on the ESB bus, which typically cause data corruption in long daisy-chained rack configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Process Uptime:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-redundant power architecture (Suffix -4) allows the node to draw current from two independent AC sources. If one power module fails, the secondary module instantly carries the full load, permitting online replacement without interrupting the control logic or field I\/O signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Path Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting the dual-redundant ESB bus, this node maintains 100% visibility of field data even if one communication cable sustains physical damage. This dual-path system ensures high-speed, 128 Mbps synchronization remains intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically engineered for the 100-120V AC standard, the internal power modules filter high-frequency transients and electromagnetic interference (EMI) common in environments with large motors and high-voltage switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require an external terminator?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/CU2T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption includes an integrated terminator. You should place this specific model at the end of an ESB bus chain to provide the necessary electrical termination for the entire segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an ANB10S with this ANB10D model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ANB10D (Duplexed) offers superior reliability compared to the ANB10S (Single). However, you must ensure your Field Control Station (FCS) has the dual-redundant ESB bus ports and cables to utilize the secondary path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with 240V AC power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Suffix \"1\" designates a 100-120V AC input. Connecting this unit to 240V AC will result in immediate hardware failure. For 240V applications, please request the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10D-420\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting accessories come with the unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard units typically include the necessary M5 mounting screws and insulation bushes. The insulation bushes are essential to prevent ground loops between the 10 kg chassis and the rack frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52763013480757,"sku":"ANB10D-410\/CU2T","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ANB10D-427CU2N_6338d00b-b493-45a3-bc9a-b2f57a9fd47c.png?v=1776668849","url":"https:\/\/www.5gplc.com\/products\/yokogawa-anb10d-410-cu2t-centum-vp-esb-bus-node-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}