{"product_id":"yokogawa-amn34-centum-rio-nest-for-multipoint-analog-i-o-modules","title":"Yokogawa AMN34 CENTUM RIO Nest for Multipoint Analog I\/O Modules","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AMN34\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a compact, specialized housing for Multipoint Analog I\/O modules within the Yokogawa Distributed Control System (DCS) environment. This nest facilitates the high-density integration of analog signals by providing a stable interface for up to two modules. It bridges the gap between field instrumentation and the processing node, ensuring precise data acquisition for critical process variables.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AMN34 adheres to strict electrical and mechanical standards for seamless RIO integration:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNest for Multipoint Analog I\/O Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Slots (Supports up to 2 analog I\/O modules)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 V DC (Supplied via Node Interface Unit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation Sites\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Control Station (FCS), I\/O Expansion Rack, NIU Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e152 mm × 127 mm x 254 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Dual-Slot Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike bulky 16-slot racks, the AMN34 utilizes a 2-slot design. This allows engineers to deploy small-scale I\/O expansion at specific node locations without wasting valuable cabinet space on unpopulated slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Voltage Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit draws power directly from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNode Interface Unit (NIU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the 5 V DC backplane. This centralized power management eliminates the need for localized AC\/DC converters and reduces the thermal footprint within the Field Control Station.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Mounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe chassis supports multiple installation configurations. Whether mounting within an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCS\u003c\/strong\u003e, an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O expansion rack\u003c\/strong\u003e, or a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNIU assembly\u003c\/strong\u003e, the AMN34 maintains structural integrity and signal alignment regardless of the cabinet layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe mechanical design shields sensitive multipoint analog signals from the electromagnetic noise typically generated by nearby high-voltage switchgear, preserving the accuracy of high-resolution analog inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this Yokogawa AMN34 unit new or refurbished?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe offer this AMN34 as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eequipment. It ships in its original factory packaging, ensuring you receive a unit with zero previous runtime and full manufacturer-grade reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the AMN34 receive its operating power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe nest utilizes a passive backplane that receives\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the connected Node Interface Unit (NIU). You do not need to wire a separate power source directly to the AMN34 chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different types of analog modules in this nest?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The AMN34 supports up to two multipoint analog I\/O modules. As long as the modules belong to the compatible Yokogawa multipoint series for your specific system version, you can combine input and output modules within the two available slots.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary considerations for mounting in an expansion rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure the expansion rack provides adequate ventilation and matches the 152 mm × 127 mm x 254 mm dimensions. We recommend verifying that the backplane connectors align perfectly before tightening mounting screws to prevent pin damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52542149198133,"sku":"AMN34","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AMN112_44d1b32e-3768-44c5-9828-1ce8148ac86d.jpg?v=1775545830","url":"https:\/\/www.5gplc.com\/products\/yokogawa-amn34-centum-rio-nest-for-multipoint-analog-i-o-modules","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}