{"product_id":"yokogawa-amm22c-mv-input-multiplexer-module-for-centum-cs-vp","title":"Yokogawa AMM22C mV Input Multiplexer Module for CENTUM CS\/VP","description":"\u003cp\u003eThe Yokogawa AMM22C is a high-precision mV input multiplexer module engineered for the CENTUM CS 3000 and CENTUM VP distributed control systems. It addresses the challenge of acquiring low-level voltage signals from dense sensor arrays by consolidating 16 isolated analog channels into a single, compact unit. This module is essential for applications requiring high-density data acquisition—such as monitoring thermocouples or shunt-based transducers—offering a cost-effective and space-saving alternative to individual transmitters while maintaining superior signal stability through channel-to-channel galvanic isolation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AMM22C is designed for high-resolution signal processing and robust industrial performance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003emV Input Multiplexer Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eAMM22C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCENTUM VP, CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e16 High-Isolation Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eLow-level DC Voltage (Millivolt Spectrum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eConversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHigh-resolution A\/D Processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eChannel-to-Channel Galvanic Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eConnection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHigh-Density System Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Code Interpretation\u003c\/h3\u003e\n\u003cp\u003eFor Yokogawa modules, the suffix code is the primary identifier for the physical interface type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAMM22C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAMM22-AXX\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA (Suffix -C):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-C\u003c\/strong\u003e: Denotes that this module uses a high-density connector interface rather than screw terminals. This design requires a specific mating cable or breakout assembly for field wiring, facilitating faster installation and cleaner cable management compared to direct wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003eNote: This is distinct from the \"T\" (Terminal) version, which would feature direct screw terminals on the module face.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003eTo ensure accurate measurement and system safety, follow these installation practices:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AMM22C is designed to mount into specific I\/O carrier boxes (such as the AMN32). Ensure the module is fully inserted into the slot and the locking mechanism is engaged to secure the connection to the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSince this is a connector-type module, you must use the designated mating cable. Ensure the connector is seated firmly and latched to prevent signal interruption caused by vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation (CJC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf using this module for thermocouple measurements, you must manage Cold Junction Compensation. This is typically handled via a compatible terminal board or by configuring the CJC parameters within the DCS engineering software to ensure accurate temperature readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Verification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features channel-to-channel galvanic isolation. This allows you to connect sensors with different common-mode voltages without creating ground loops, but proper system grounding is still required for noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AMM22C be used directly with thermocouples?\u003c\/strong\u003eA: Yes, the AMM22C can process the millivolt signals generated by thermocouples. However, for accurate temperature readings, you must ensure Cold Junction Compensation (CJC) is properly configured, either through the hardware terminal board or the DCS software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the \"C\" (Connector) version?\u003c\/strong\u003eA: The connector interface allows for pre-fabricated cabling, which significantly reduces wiring time and improves the aesthetics and maintainability of the control panel compared to direct screw-terminal wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the AMM22C compatible with CENTUM VP?\u003c\/strong\u003eA: Yes, this module is fully compatible with both CENTUM CS 3000 and the newer CENTUM VP systems, making it a versatile choice for system upgrades and maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle signal interference?\u003c\/strong\u003eA: The AMM22C features channel-to-channel galvanic isolation. This prevents ground loops and electrical noise from one channel from affecting others, ensuring high signal integrity in noisy industrial environments.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52522752377141,"sku":"AMM22C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AMM22_afb67bc4-6f86-4c34-8583-28e6fcd7aaed.jpg?v=1775034779","url":"https:\/\/www.5gplc.com\/products\/yokogawa-amm22c-mv-input-multiplexer-module-for-centum-cs-vp","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}