{"product_id":"yokogawa-aip831-101-centum-vp-eight-loop-operation-keyboard","title":"Yokogawa AIP831-101 CENTUM VP Eight-Loop Operation Keyboard","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AIP831-101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized Human Interface Station (HIS) peripheral for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem. It enables operators to manage eight process loops simultaneously, drastically improving response times in high-pressure control room environments. This flat-profile keyboard integrates touch-sensitive sensors that trigger the \"Instrument Faceplate Highlight\" function upon contact. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compatibility with your desktop-type HIS workstations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AIP831-101 utilizes high-speed USB bus power to drive both tactile input and audio feedback:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeyboard Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlat membrane with eight-loop dedicated control keys\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTouch Sensors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated sensors for automatic faceplate highlighting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAudio Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndependent USB speaker for alarms and buzzing sounds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePC Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual USB A-type connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSB 2.0 (Keyboard) \/ USB 1.1 (Audio)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Color:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBlack (Munsell No. N1.5)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 to 40°C (Normal operation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 to 80% RH (Non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires LHS1140 Eight-loop Simultaneous Operation Package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe AIP831-101 optimizes the operator's interface with the DCS through several technical innovations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTactile Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dedicated 8-loop key layout eliminates the need to toggle through multiple software menus. Operators adjust setpoints and outputs across eight different controllers with physical keys, reducing the risk of manual entry errors during critical process upsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Visual Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContact with the touch-sensitive keys instantly highlights the corresponding instrument faceplate on the HIS monitor. This hardware-to-software synchronization allows the operator to verify the target loop without shifting focus between the screen and the desk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Alarm Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe included USB speaker provides localized audible alerts. This ensures that the operator hears critical alarms directly at their station, even in noisy control rooms, without relying on central console speakers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module draws power directly from the USB bus. This eliminates the need for external power supplies and simplifies cable management in cramped desktop environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich CENTUM VP software versions support the AIP831-101?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou must use CENTUM VP R5.03 or later. Additionally, the system must run the LHS1100 or LHM1101 Standard Operation and Monitoring function. Note that this keyboard does not support LHS1120 or LHS1130 packages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this keyboard require a separate power cable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The AIP831-101 operates entirely on USB bus power. It utilizes two USB Type-A connectors to manage both the keyboard input signals and the sound function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I connect multiple AIP831 units to a single HIS?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa specifications restrict usage to one AIP831 per Desktop Type HIS workstation to ensure stable driver communication and power distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the \"Instrument Faceplate Highlight\" feature automatic?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. Once you touch the sensors on the control keys, the software package (LHS1140) automatically identifies the loop and brings the corresponding faceplate to the foreground on the HIS display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551534248245,"sku":"AIP831-101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AIP831-101.jpg?v=1775730160","url":"https:\/\/www.5gplc.com\/products\/yokogawa-aip831-101-centum-vp-eight-loop-operation-keyboard","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}