{"product_id":"yokogawa-aip602-centum-vp-door-fan-unit","title":"Yokogawa AIP602 CENTUM VP Door Fan Unit","description":"\u003ch3\u003e\u003cstrong\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProduct Overview\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u003c\/span\u003eThe Yokogawa \u003cstrong\u003eAIP602\u003c\/strong\u003e Door Fan Unit is a critical thermal management component designed specifically for Yokogawa CENTUM VP and CS series control station cabinets. In high-density DCS installations, heat accumulation within enclosed racks can lead to processor throttling, communication errors, or premature component failure. The AIP602 solves this by providing active, regulated airflow directly through the cabinet door, maintaining optimal internal temperatures without compromising the enclosure's IP54 protection rating against dust and water splashes. This ensures continuous reliability for process control systems in demanding environments such as power plants, oil refineries, and chemical processing facilities.\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable class=\"qwen-markdown-table\"\u003e\n\u003cthead class=\"qwen-markdown-table-thead\"\u003e\n\u003ctr class=\"qwen-markdown-table-thead-tr firstRow\"\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"qwen-markdown-table-tbody\"\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eModel Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eAIP602\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eManufacturer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa Electric Corporation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eDoor Fan Unit (Cooling Fan)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCompatible Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eCENTUM VP, CENTUM CS 3000, CS 1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eFan Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eHigh-efficiency axial flow fan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eAirflow Capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e28.3 CFM (Cubic Feet per Minute) typical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eFan Speed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e3,000 RPM (Revolutions Per Minute) typical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eNoise Level\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e≤ 50 dB(A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePower Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eStandard AC (Typically 100-240 VAC, 50\/60 Hz)*\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eOperating Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e-20°C to +70°C (-4°F to +158°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eProtection Class\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eIP54 (Dust protected, splash proof)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eDimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e160 mm (W) x 120 mm (H) x 35 mm (D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eUnit Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e3.0 kg (Includes housing and mounting hardware)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eInsulation Resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u0026gt;100 MΩ at 500 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eDielectric Strength\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e1,500 VAC for 1 minute\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eControl Feature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eIntegrated temperature sensor for automatic regulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003e*\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003eNote: While specific voltage markings should be verified on the unit label, Yokogawa door fan units typically support universal AC input suitable for global industrial standards.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eModel Code Decomposition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa’s naming convention for peripheral cooling units like the AIP602 is streamlined to identify the function and compatibility series. Unlike variable-length cables or configurable I\/O modules, this unit is a fixed-specification assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePart Number: AIP602\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eAI\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Identifies the hardware series within the Yokogawa CENTUM VP\/CS family, covering standard peripherals and interface units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eP\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Denotes the \"Peripheral\" functional category. In this context, it signifies auxiliary equipment such as fans, power supplies, or conversion units that support the main logic racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e602\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The unique designator for the Door Mount Fan Unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e\"6\"\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e series typically relates to cooling, power distribution, and rack accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e\"02\"\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e sequence specifically identifies the form factor (160mm x 120mm) and the IP54 rated housing designed for direct door integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSuffix Logic\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The base part number \u003c\/span\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eAIP602\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e represents the complete assembly including the fan, grill, filter, and temperature sensor. It does not typically utilize variable alphanumeric suffixes for voltage or speed in standard procurement, as the unit is engineered with a universal AC motor and fixed airflow characteristics. Any revision updates (e.g., improved bearing technology) are managed internally by Yokogawa without changing the primary part number, ensuring drop-in replacement compatibility for legacy systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eInstallation Recommendations and Wiring Guidelines\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eCorrect installation of the AIP602 is vital to ensure effective cooling while maintaining the environmental seal of the control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003col class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCutout Preparation\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Verify the cutout dimensions on the cabinet door match the AIP602 footprint (160 mm x 120 mm). Ensure the edges are deburred to prevent damage to the unit's gasket, which is critical for maintaining the IP54 rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eAirflow Direction\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Install the unit with the correct airflow orientation. Typically, the AIP602 is configured to exhaust hot air from the top of the rack or intake cool air from the bottom, depending on the overall cabinet thermal design. Check the arrow indicator on the fan housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eElectrical Connection\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Connect the power supply to a dedicated AC source with appropriate overcurrent protection. Given the dielectric strength of 1,500 VAC, ensure all wiring is insulated and routed away from high-voltage power lines to prevent induced noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSensor Placement\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: If the unit includes an external temperature probe (depending on specific sub-configuration), position the sensor near the hottest point of the rack (usually the top CPU module) to ensure accurate thermal regulation and fan speed modulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eFilter Maintenance\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The AIP602 includes an air filter to prevent dust ingress. Establish a regular maintenance schedule to clean or replace this filter, especially in dusty industrial environments, to prevent airflow restriction and motor overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSealing\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Apply additional silicone sealant around the mounting frame if the cabinet is located in a washdown area or extremely humid environment to reinforce the IP54 seal.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Can the AIP602 be used in outdoor cabinets?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The AIP602 has an IP54 rating, which protects against dust and water splashes from any direction. While suitable for sheltered outdoor locations or harsh indoor environments, it should not be directly exposed to heavy rain jets or submersion. For full outdoor exposure, an additional weather shield or higher-rated enclosure is recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Is the fan speed adjustable?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Yes, the AIP602 is equipped with temperature sensors that automatically regulate fan speed based on the internal cabinet temperature. This feature reduces noise and extends fan life during cooler operating periods while maximizing airflow during peak heat loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: How loud is the AIP602 during operation?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The unit operates at a maximum noise level of 50 dB(A). This is comparable to a quiet conversation, making it suitable for control rooms where operators are present, though it may be audible in very quiet environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: What is the expected lifespan of the fan bearings?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Yokogawa industrial fans are designed for continuous duty (24\/7) with high-quality ball bearings. Under normal operating conditions (ambient temperature \u0026lt;40°C and regular filter cleaning), the expected service life typically exceeds 50,000 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Does the AIP602 fit older CENTUM CS 1000 racks?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Yes, the AIP602 is designed with a standard form factor compatible with most CENTUM VP and CS 3000\/1000 series control station doors. However, always verify the door cutout dimensions before ordering for very legacy or custom-built racks.\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52521981804853,"sku":"AIP602","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AIP602.png?v=1775025291","url":"https:\/\/www.5gplc.com\/products\/yokogawa-aip602-centum-vp-door-fan-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}