{"product_id":"yokogawa-aip502-centum-vp-v-net-coupler-module","title":"Yokogawa AIP502 Centum VP V-Net Coupler Module","description":"\u003ch2\u003e\u003cspan class=\"qwen-markdown-text\"\u003eProduct Title\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAIP502\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eV-Net Coupler Module acts as the critical gateway between Yokogawa’s proprietary high-speed V-Net control bus and standard industrial Ethernet networks. It resolves the isolation challenge often found in legacy DCS architectures by enabling seamless, real-time data exchange between Centum VP Field Control Stations (FCS) and third-party systems utilizing protocols such as Ethernet\/IP, Modbus TCP, PROFINET IO, and EtherCAT. This module eliminates the need for complex, external protocol converters, reducing latency and potential points of failure in large-scale process automation. By supporting communication speeds up to 100 Mbps via standard RJ45 interfaces, the AIP502 ensures that vital process data reaches historians, PLCs, and asset management systems with the determinism required for safe and efficient plant operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable class=\"qwen-markdown-table\"\u003e\n\u003cthead class=\"qwen-markdown-table-thead\"\u003e\n\u003ctr class=\"qwen-markdown-table-thead-tr firstRow\"\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eParameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"qwen-markdown-table-thead-tr-th\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"qwen-markdown-table-tbody\"\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eProduct Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eV-Net Coupler Module \/ Communication Gateway\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eBrand \/ Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eYokogawa \/ Centum VP Compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eAIP502\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eSupported Protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eEthernet\/IP, Modbus TCP, PROFINET IO, EtherCAT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eCommunication Speed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eUp to 100 Mbps (Fast Ethernet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePhysical Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eRJ45 Ports (Standard Copper Ethernet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eBus Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eV-Net (Yokogawa Proprietary Control Bus)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eDimensions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e15.2 cm (W) × 7.6 cm (H) × 25.4 cm (D)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eWeight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003e0.6 kg (1.32 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eMounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eDedicated slot in Centum VP Node Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eData Transfer Mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eFull-duplex switching for high throughput\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qwen-markdown-table-tbody-tr\"\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePrimary Application\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"qwen-markdown-table-tbody-tr-td\"\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eMulti-vendor system integration, Data Historian connectivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eModel Code Decomposition\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eThe Yokogawa AIP502 adheres to the strict naming conventions of the Centum VP communication hardware family. As a dedicated protocol conversion and coupling unit, it utilizes a fixed functional designation without variable suffixes for standard orders.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003ePart Number: AIP502\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eAI\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Identifies the module category within the Centum architecture, specifically denoting Interface or Communication functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eP\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Specifies the hardware platform series, confirming compatibility with the Centum VP node backplane and chassis structure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003e502\u003c\/span\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: The unique functional identifier for the V-Net Coupler capable of bridging V-Net traffic to multiple Industrial Ethernet protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"qwen-markdown-list list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cem\u003eNote\u003c\/em\u003e\u003cspan class=\"qwen-markdown-text\"\u003e: Unlike analog I\/O modules that often require suffixes to define terminal block types or intrinsic safety barriers (e.g., -S1, -H2), the AIP502 is a self-contained communication processor. The base model number \"AIP502\" fully defines its protocol stack capabilities and physical interface. Specific protocol activation (e.g., enabling only Modbus TCP vs. PROFINET) is typically managed via software licensing or configuration parameters within the Vx-Toolset engineering environment, rather than distinct hardware suffixes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eInstallation Recommendations and Wiring Guidelines\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eInstallation of the AIP502 requires careful attention to network segmentation and physical layer integrity. Insert the module into the designated communication slot of the Centum VP node unit while the system is powered down, or utilize hot-swapping procedures if the node configuration supports it and redundancy is active. Ensure the module is firmly seated to maintain reliable contact with the V-Net backplane traces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eFor Ethernet connectivity, use Category 5e or Category 6 shielded twisted-pair (STP) cables terminated with high-quality RJ45 connectors. In industrial environments with heavy machinery or variable frequency drives (VFDs), shielding is critical to prevent electromagnetic interference (EMI) from corrupting high-speed data packets. Ground the cable shield at one end only (typically the switch side) to avoid ground loops, unless the specific facility grounding strategy dictates otherwise. Connect the RJ45 port to an industrial-grade managed switch configured for the specific protocol requirements (e.g., setting up VLANs for PROFINET or adjusting packet intervals for EtherCAT). Verify link status via the module’s front-panel LEDs; a solid green light indicates a successful 100 Mbps link, while amber may indicate a 10 Mbps fallback or negotiation error. After physical installation, download the communication configuration from the Engineering Station to activate the specific protocol drivers on the AIP502.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"qwen-markdown-heading\"\u003e\u003cspan class=\"qwen-markdown-text\"\u003eFrequently Asked Questions (FAQ)\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Can the AIP502 run multiple protocols simultaneously?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Yes, the AIP502 is designed with a multi-protocol stack. It can handle concurrent communication sessions for Ethernet\/IP, Modbus TCP, PROFINET IO, and EtherCAT, subject to the processing load limits of the specific firmware version and the bandwidth capacity of the 100 Mbps link. Configuration of simultaneous protocols is managed via the Centum VP engineering software.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Is the AIP502 compatible with Gigabit Ethernet networks?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The AIP502 hardware interface operates at speeds up to 100 Mbps (Fast Ethernet). While it can physically connect to a Gigabit Ethernet switch, the link will negotiate down to 100 Mbps. For applications requiring Gigabit throughput, a different model or an external high-speed gateway architecture may be necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: Does this module replace the need for external gateways?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: In most standard integration scenarios, yes. The AIP502 natively supports major industrial protocols, eliminating the need for third-party hardware gateways that introduce additional latency, power requirements, and maintenance overhead. It integrates directly into the Centum VP node, simplifying the cabinet layout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: How is the communication configuration managed?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: Configuration is performed using Yokogawa’s Vx-Toolset engineering software. Engineers define the V-Net tags to be exposed, map them to the specific protocol registers (e.g., Modbus holding registers, PROFINET I\/O mapping), and set update rates. The configuration is then downloaded to the Field Control Station (FCS) where the AIP502 resides.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-strong\"\u003eQ: What happens to communication if the V-Net side fails?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qwen-markdown-text\"\u003eA: The AIP502 monitors the health of the V-Net connection. If the V-Net link is lost, the module will typically flag a communication error to the connected Ethernet devices (depending on protocol specifics) and cease updating process values to prevent stale data usage. Alarms are generated within the Centum VP operator station to alert personnel of the gateway status.\u003c\/span\u003e\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52522678976821,"sku":"AIP502","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AIP5024.jpg?v=1775030795","url":"https:\/\/www.5gplc.com\/products\/yokogawa-aip502-centum-vp-v-net-coupler-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}