{"product_id":"yokogawa-afv30d-a41252-centum-vp-duplexed-field-control-unit","title":"Yokogawa AFV30D-A41252 CENTUM VP Duplexed Field Control Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AFV30D-A41252\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estands as a cornerstone of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control System (DCS). This Duplexed Field Control Unit (FCU) executes complex control logic and manages high-speed communication between Vnet\/IP and FIO modules. Designed for mission-critical automation, the duplexed architecture ensures that the secondary processor takes control instantly if the primary unit fails. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your plant architecture benefits from the latest R6.01+ hardware standards.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown: AFV30D-A41252\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes a detailed suffix structure to define the redundancy and power configurations of the AFV30D series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAFV30D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDuplexed Field Control Unit (Vnet\/IP and FIO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard type for CP471 processors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual-redundant Vnet\/IP and Dual-redundant power supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220-240 V AC Power Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type (Non-explosion protection)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSoftware\/Hardware R6.01 or later\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AFV30D-A41252 incorporates heavy-duty hardware to handle massive I\/O throughput:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports Duplexed CP471 Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant Vnet\/IP interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e220 V to 240 V AC, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch Rack Mountable (requires 4U space)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCPU, Power Supply, and Network redundancy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCENTUM VP R6.01 and subsequent versions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard industrial (Non-corrosive\/Non-hazardous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe AFV30D-A41252 solves the most pressing availability and integration challenges in process automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Downtime Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dual-redundant power supply and CPU architecture allow for \"Hot Swapping.\" Maintenance teams replace power modules or CPUs while the process remains live, eliminating the need for scheduled shutdowns during hardware refreshes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVnet\/IP Network Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing dual-redundant Vnet\/IP paths, the unit maintains high-speed data synchronization even if one network cable or switch fails. This ensures the operator console always receives real-time field data without latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Rack Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 19-inch rack-mountable design fits into standard industrial enclosures. This allows engineers to consolidate control hardware and power distribution into a unified footprint, simplifying cabinet thermal management and cable routing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically configured for 220-240V AC environments, the internal power units handle the voltage fluctuations common in large-scale industrial grids, protecting the sensitive logic circuits from power surges or brownouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AFV30D-A41252 include the CPU modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe base AFV30D-A41252 unit provides the chassis, backplane, and redundant power supplies. You must order the CP471 CPU modules separately to complete the duplexed control set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this unit in a hazardous environment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"5\" code in the suffix indicates a basic type with no explosion protection. For installations in Zone 2 or Division 2 areas, you must house the unit in an appropriately certified pressurized or explosion-proof enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with CENTUM CS 3000?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile Yokogawa hardware often shares lineage, the AFV30D-A41252 (Revision 2) targets CENTUM VP R6.01 or later. Check your specific project software version to ensure full driver and functional compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting hardware do I need for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit slides into any standard 19-inch rack. We recommend using heavy-duty L-brackets or rack shelves to support the 9 kg weight and ensure long-term mechanical stability against plant vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52750569668917,"sku":"AFV30D-A41252","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AFV10D-S411012_b1ea0f0f-1fb8-4946-9914-c5929772c666.jpg?v=1776654618","url":"https:\/\/www.5gplc.com\/products\/yokogawa-afv30d-a41252-centum-vp-duplexed-field-control-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}