{"product_id":"yokogawa-aea4d-06-terminal-board-for-analog-i-o","title":"Yokogawa AEA4D-06 Terminal Board for Analog I\/O","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AEA4D-06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized 16-channel analog terminal board designed for both single and dual-redundant configurations. It facilitates the critical connection between field instruments and the CENTUM series control system. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing a modern, high-durability interface for industrial signal processing.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe AEA4D series follows a modular suffix logic to define environmental protection and surge capabilities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAEA4D:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminal Board for Analog (16-channel, supports redundancy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithout surge absorber (Standard high-density footprint)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e6:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA Standard G3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econformal coating option; configured without explosion protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe AEA4D-06 integrates seamlessly with standard Yokogawa signal cables and I\/O modules.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Single or Dual-Redundant I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Cable\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKS1 Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA Standard G3 (Harsh environment resistance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone (Suffix 0)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AEA4D-06 features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA Standard G3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompliance. This technical treatment protects the circuitry against corrosive atmospheric gases such as\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$H_2S$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$SO_2$\u003c\/span\u003e, preventing silver\/copper whiskers and ensuring long-term operation in wastewater or chemical processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis board supports dual-redundant wiring. It maintains continuous signal flow even during a single module failure, providing a high-availability solution for critical control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Replacement Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis model functions as the official replacement for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D-01\u003c\/strong\u003e. It utilizes the same mounting footprint and KS1 cable interface, allowing engineers to upgrade aging systems without rewiring the entire cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal arrangement optimizes space for 16-channel analog signals, reducing cabinet clutter and streamlining the transition from field multi-cores to system cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the AEA4D-06 to replace an existing AEA4D-01 board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Yokogawa designates the AEA4D-06 as the official product replacement for the AEA4D-01. It maintains form, fit, and function compatibility while providing the enhanced G3 environmental rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this board require a specific cable for connection to the I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AEA4D-06 requires the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS1 connection cable\u003c\/strong\u003e. Ensure you select the correct length of the KS1 cable to match your cabinet layout for optimal signal integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the environmental limitations of the G3 option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe G3 option permits installation in environments where harsh gases exist, specifically defined by the ISA-S71.04 standard. However, this specific model (Suffix 6) does not include explosion-proof certifications; therefore, you must install it in a non-hazardous area or within an appropriately rated enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this terminal board factory sealed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We ship all AEA4D-06 units as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein original Yokogawa factory packaging, complete with the manufacturer’s serial number and quality control markings.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550525518133,"sku":"AEA4D-06","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AEA4D-06.jpg?v=1775719945","url":"https:\/\/www.5gplc.com\/products\/yokogawa-aea4d-06-terminal-board-for-analog-i-o","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}