{"product_id":"yokogawa-adv551-p00-centum-vp-32-channel-digital-output-module","title":"Yokogawa ADV551-P00 CENTUM VP 32-Channel Digital Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV551-P00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density discrete control interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems (DCS). This module manages 32 independent isolated output channels, driving field devices such as solenoid valves, relays, and indicator lamps. Beyond standard status switching, the \"P\" configuration enables advanced pulse width and time-proportional output functions, allowing the DCS to modulate field equipment with high temporal precision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original Factory Sealed.\u003c\/p\u003e\n\u003ch2\u003ePart Number Breakdown: ADV551-P00\u003c\/h2\u003e\n\u003cp\u003eYokogawa utilizes specific coding to define the functional capabilities of the ADV551 series:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eADV551:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module (32-channel, 24 V DC, Isolated).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with Pulse Width Output and Time-Proportional Output functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic Type hardware specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard internal sub-component version.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe ADV551-P00 provides robust switching performance and rapid response times for critical control loops.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32, Isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Load Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA per channel (at 26.4 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (Status)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 3 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time (Pulse)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical Isolation between system and field\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.7 cm x 13 cm x 3.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Pulse Width Modulation (PWM):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ADV551-P00 executes time-proportional control directly at the module level. This hardware-based execution offloads processing tasks from the main controller CPU, ensuring precise pulse timing for dosing pumps or heating elements without logic scan-time jitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Control Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging 32 outputs within a compact 10.7 cm depth module maximizes I\/O density. This allows engineers to reduce the number of required subracks and control cabinets, significantly lowering the total cost of installation and space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Response Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA status output response time of 3 ms or less ensures near-instantaneous command execution. This rapid switching is vital for safety interlocks and high-speed sequence-of-events (SOE) applications where millisecond precision prevents equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical isolation protects the internal DCS bus from field-side electrical surges and ground loops. This architecture ensures that a localized short circuit on a field actuator does not propagate to the central safety logic or neighboring modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports integrated diagnostic feedback. Maintenance teams can identify channel-specific faults or power supply anomalies through the CENTUM system software, reducing MTTR (Mean Time To Repair).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the ADV551-P00 replace a standard ADV551-S module?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The \"P\" version includes all the status output capabilities of the \"S\" version but adds pulse width functionality. Ensure your system software configuration reflects the specific hardware features to utilize the advanced timing functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the time-proportional output function?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis function allows you to control devices that require a specific \"on-time\" ratio within a fixed period, such as solid-state relays for industrial heaters, providing quasi-analog control using discrete digital hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external protection for inductive loads?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the ADV551-P00 includes internal protection, we recommend installing external flyback diodes across large inductive loads (like heavy-duty solenoid valves) to extend the life of the output transistors and minimize EMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ADV551-P00 suitable for driving high-current motor starters?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports 100 mA per channel. For high-current motor starters or large contactors exceeding this rating, you must use interposing relays to prevent overloading the module's output circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52471248027957,"sku":"ADV551-P00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV551-P00.jpg?v=1774331477","url":"https:\/\/www.5gplc.com\/products\/yokogawa-adv551-p00-centum-vp-32-channel-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}