{"product_id":"yokogawa-adv169-p50-centum-vp-64-channel-digital-i-o-module","title":"Yokogawa ADV169-P50 CENTUM VP 64-Channel Digital I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV169-P50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density hybrid interface for the CENTUM VP Integrated Production Control System. This 64-channel module facilitates both digital status acquisition and transistor-driven outputs within a single FIO slot, streamlining the architecture of complex automated environments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compliance with factory-level timing and isolation standards for critical process control.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe suffix configuration of the ADV169 defines its specific functional and visual interface:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eADV169:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase 64-Channel Digital Input\/Output Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated pushbutton function for local manual input and diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStatus display omitted (no front-panel LED indicators).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic type with standard industrial environmental ratings (no explosion protection).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ADV169-P50 delivers precision logic and high-speed data handling:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 Channels (Hybrid Input\/Output)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLogic Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransistor-driven status outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital status acquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotocoupler isolation (Channel-to-System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Pushbutton\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVisual Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo LED indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 64-channel high-density design consolidates I\/O points that typically require two separate modules. This reduces the number of FIO nodes and baseplates needed, directly lowering cabinet hardware costs and heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePhotocoupler isolation shields the internal system bus from field-side electrical noise and surges. This barrier prevents transient interference from disrupting the central processor's logic execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Manual Interaction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated pushbutton enables local manual input for diagnostics. Operators can trigger specific logic states directly at the rack, accelerating loop testing and commissioning without requiring a remote HMI station for every step.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes optimized high-speed logic for real-time status acquisition. This ensures the DCS captures rapid signal transitions instantly, which is vital for high-speed interlocking and safety-related sequence monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of using a hybrid I\/O module like the ADV169-P50?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt combines input and output capabilities in one unit, making it perfect for applications where you need to monitor a status and provide a control signal in the same geographical area of the plant, significantly saving rack space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or used Yokogawa part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We guarantee this product is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It ships in original factory packaging with a full assurance of its technical integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module show channel status on the front panel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \"5\" suffix indicates that this version omits the LED status display. Use the CENTUM VP software station for channel monitoring and diagnostic feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle high-voltage AC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module operates on a 24 V DC logic level and utilizes transistor outputs. For high-voltage AC loads, you must use interposing relays to prevent damage to the transistor circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52571500216629,"sku":"ADV169-P50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV169-P00_02a1002f-7495-4c2b-b6f0-0f22b5a10d8f.jpg?v=1776233486","url":"https:\/\/www.5gplc.com\/products\/yokogawa-adv169-p50-centum-vp-64-channel-digital-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}