{"product_id":"yokogawa-adv151-p03-centum-vp-digital-input-module","title":"Yokogawa ADV151-P03 CENTUM VP Digital Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV151-P03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density discrete signal interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems (DCS). This module captures 32 independent digital signals from field equipment, such as limit switches, motor starter auxiliary contacts, and pushbutton stations. The \"P03\" designation specifically identifies the hardware configuration designed for direct pressure-clamp terminal connections, allowing for streamlined wiring without the need for intermediate external terminal boards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original Factory Sealed.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe ADV151-P03 provides a rugged electrical interface for processing binary data across large-scale industrial networks.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32, isolated (in groups)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC (Dry contact or Voltage input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.1 mA (at 24 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eON Voltage\/Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18 to 26.4 V DC \/ ≥ 3.0 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOFF Voltage\/Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≤ 5.0 V DC \/ ≤ 1.0 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC between input and system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Update Cycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure-clamp terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 mA (5 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessing 32 channels within a single slot maximizes I\/O density. This reduces the number of required subracks and nodes, lowering the total hardware footprint and simplifying cabinet thermal management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features 1500 V AC isolation between the field-side inputs and the internal DCS system bus. This protection prevents high-voltage transients and electromagnetic noise from affecting the central processor, ensuring overall system stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Status Updates:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 10 ms data update cycle enables the DCS to respond nearly instantaneously to field status changes. This speed is essential for high-speed interlocking, sequence-of-events (SOE) recording, and motor control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Wiring Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"P\" (Pressure-clamp) configuration allows for direct wiring to the module's terminal block. This eliminates the need for KS cables and separate terminal boards in many applications, reducing the number of potential failure points in the signal loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ADV151-P03 incorporates internal digital filtering to eliminate \"chatter\" from mechanical contacts. This ensures the DCS receives clean, debounced signals even from aging field switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ADV151-P03 require an external power supply for the field contacts?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must provide an external 24V DC supply to power the field-side contacts (wetting voltage). The module senses the presence or absence of this voltage to determine the logic state (ON\/OFF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between ADV151-P03 and ADV151-E03?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"P\" version uses pressure-clamp terminals for direct wiring, whereas the \"E\" version typically refers to a configuration intended for extension cable (KS cable) connections to a separate terminal board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ADV151-P03 hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a redundant I\/O configuration, you can replace the module while the system is live. In non-redundant setups, pulling the module will cause all 32 inputs to drop to an \"OFF\" or fail-safe state. Always follow facility bypass procedures before a swap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for high-voltage AC inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The ADV151-P03 is strictly rated for 24V DC. For 110V or 220V AC inputs, you must use a dedicated AC input module or interposing relays to step the voltage down to 24V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52471037002037,"sku":"ADV151-P03","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV151-P03.png?v=1774324526","url":"https:\/\/www.5gplc.com\/products\/yokogawa-adv151-p03-centum-vp-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}