{"product_id":"yokogawa-adv142-p03-centum-vp-ac-digital-input-module","title":"Yokogawa ADV142-P03 CENTUM VP AC Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV142-P03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized AC digital input module for the CENTUM VP Integrated Production Control System. It interfaces high-voltage field signals (200 to 240 V AC) directly with the control logic, providing 16 isolated channels for status monitoring and pushbutton pulse detection. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring full compliance with factory safety certifications and long-term system integrity.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe suffix logic for the ADV142 series defines specific environmental and functional capabilities:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eADV142:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase 16-Channel AC Digital Input Module (200-240 V AC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-P:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports both Status Input and Pushbutton Edge Detection functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e0:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic type with standard terminal configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA Standard G3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econformal coating and extended temperature hardware for harsh industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ADV142-P03 utilizes robust electrical parameters to handle high-voltage industrial inputs:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Common every 8 channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 to 240 V AC, 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput ON Voltage (Peak)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 V AC (226 V) to 264 V AC (373 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput OFF Voltage (Peak)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 40 V AC (56 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypical Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.2 mA per channel (at 240 V \/ 60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 kV AC (Signal to System)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 160 ms (Status Input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Direct Sensing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module eliminates the need for interposing relays when monitoring 240V AC motor starters or heavy-duty limit switches. By accepting high-voltage inputs directly, it reduces cabinet complexity and potential points of failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Isolation Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 2 kV AC withstanding voltage barrier protects the internal system bus from field-side transients. The module also maintains 1.35 kV AC isolation between commons, preventing cross-channel interference in complex electrical grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDebounced Pulse Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor manual operator consoles, the pushbutton input function recognizes pulses with a minimum ON detection time of 200 ms. This hardware-level filtering ensures accurate signal capture without requiring extensive software debouncing logic in the DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the ADV142-P03 handle frequency fluctuations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module operates reliably across both 50 Hz and 60 Hz power systems, maintaining consistent input current and response timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a Brand New unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We guarantee that every ADV142-P03 we provide is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and original factory stock\u003c\/strong\u003e. We do not sell refurbished or used components for mission-critical DCS applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"Common every 8 channels\" specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis design groups the 16 channels into two banks of 8. This allows you to monitor signals from two different AC power sources or phases within a single module while maintaining electrical separation between the banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ADV142-P03 supports online replacement within a CENTUM VP FIO node, provided the user follows Yokogawa’s standard hot-swap procedures to ensure continuous system operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52571508867381,"sku":"ADV569-P50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV169-P00_72981f2c-cd5d-40f8-a885-1103bd96ae6b.jpg?v=1776233693","url":"https:\/\/www.5gplc.com\/products\/yokogawa-adv142-p03-centum-vp-ac-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}