{"product_id":"yokogawa-aam51-s1-centum-output-module","title":"YOKOGAWA AAM51 S1 CENTUM Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA AAM51 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAAM51\u003c\/strong\u003e Current\/Voltage Output Module, operates as a dedicated hardware component for direct process output driving of valves and actuators within YOKOGAWA CENTUM system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAM51 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e38 mA or lower (24.0 VDC), 10 mA or lower (5.0 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Range\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Limit\u003c\/td\u003e\n\u003ctd\u003e25.5 VDC or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e2 ms or 22 ms (for step response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Withstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute; 42 VDC field-to-system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMounted on the nest for I\/O adaptor (A2BA3D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Field Signal Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe AAM51 S1 generates software-configurable 4 to 20 mA DC current signals to drive final control elements such as control valves and positioners across process control loops. The card provides galvanic signal isolation rated at 1500 VAC for 1 minute and 42 VDC between field circuits and system backplane logic, suppressing ground loop currents and common-mode noise propagation. Signal routing operates in conjunction with standard 4-20 mA HART loop protocol field devices across CENTUM node nests.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the current consumption rating of the AAM51 S1 module?\u003c\/p\u003e\n\u003cp\u003eA: The module consumes 38 mA or lower from the 24.0 VDC supply rail and 10 mA or lower from the 5.0 VDC backplane logic rail.\u003c\/p\u003e\n\u003cp\u003eQ: How is the AAM51 S1 output module physically mounted in the system?\u003c\/p\u003e\n\u003cp\u003eA: The module mounts directly onto an A2BA3D I\/O adaptor nest for backplane inter-module connectivity.\u003c\/p\u003e\n\u003cp\u003eQ: What response time configuration options are available for the output signal update?\u003c\/p\u003e\n\u003cp\u003eA: The data update period can be configured to 2 ms or 22 ms depending on system step response requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePower down the I\/O adaptor nest before installing or removing the AAM51 S1 module. Observe static safety measures by wearing a grounded ESD wrist strap while handling the unit. Align the card with the mounting slots on the A2BA3D I\/O adaptor nest and press firmly until backplane connectors seat completely, then fasten retaining hardware to establish solid frame grounding. Ensure output cabling for 4 to 20 mA DC loops uses shielded twisted-pair cables, bonding the shield at a single earth termination point inside the control cabinet. Route signal lines separately from high-voltage AC power conductors.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":53278722490677,"sku":"AAM51 S1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AAM51S1.png?v=1786613610","url":"https:\/\/www.5gplc.com\/products\/yokogawa-aam51-s1-centum-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}