{"product_id":"woodward-9907-028-spm-a-synchronizer","title":"Woodward 9907-028 SPM-A Synchronizer","description":"\u003cp\u003eConfigured for generator synchronization and phase alignment in parallel power systems, the \u003cstrong\u003eWoodward 9907-028\u003c\/strong\u003e (\u003cstrong\u003e9907-028\u003c\/strong\u003e Synchronizer) provides direct physical\/electrical execution of generator speed matching and breaker closure signaling.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9907-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg (5 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-45 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input\u003c\/td\u003e\n\u003ctd\u003e115\/230 VAC RMS (+\/- 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Angle\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 deg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response\u003c\/h3\u003e\n\u003cp\u003eThe 9907-028 synchronizer modulates prime mover rotational speed to align the generator phase angle within a +\/- 10 deg window relative to the bus. To achieve a stable actuator loop feedback response, the device integrates adjustable dynamic settings that allow for precise tuning of the frequency correction output. The controller interfaces with external speed governors, such as the 2301 or EPG series, to influence engine speed without performing voltage matching. The internal logic provides four selectable operational modes—RUN, CHECK, PERMISSIVE, and OFF—which dictate the synchronization behavior and the activation of the circuit breaker closure signals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 9907-028 perform automatic voltage matching during synchronization?\u003c\/p\u003e\n\u003cp\u003eA: No, this model does not feature voltage matching capabilities. It focuses exclusively on phase angle and frequency matching to facilitate parallel operation.\u003c\/p\u003e\n\u003cp\u003eQ: How do the different operational modes (RUN, CHECK, PERMISSIVE) affect synchronization?\u003c\/p\u003e\n\u003cp\u003eA: RUN mode enables full synchronization and breaker closure signals. CHECK mode performs synchronization calculations but inhibits breaker closure. PERMISSIVE mode allows synchronization monitoring but restricts the unit from modifying the engine speed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the synchronizer within a switchgear enclosure. Ensure adequate ventilation to maintain operation within the rated -45 to 70 deg C range, though optimal stability is observed between 10 deg C and 30 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cabling for all sensing inputs (bus\/generator voltage) and control outputs to prevent electrical noise interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Configuration:\u003c\/strong\u003e Install a user-defined multi-position switch to toggle between the four operational states. Verify the wiring of the switch inputs corresponds to the desired mode definitions (RUN, CHECK, PERMISSIVE, OFF).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e During initial commissioning, monitor the phase angle error and frequency drift. Adjust internal dynamic settings as necessary to achieve smooth synchronization without excessive speed hunting or oscillation before breaker closure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53002251796789,"sku":"9907-028","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/9907-028.png?v=1781513764","url":"https:\/\/www.5gplc.com\/products\/woodward-9907-028-spm-a-synchronizer","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}