{"product_id":"woodward-9905-969-linknet-6-channel-analog-input-module","title":"Woodward 9905-969 Linknet 6 Channel Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 9905-969\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e9905-969\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for distributed signal acquisition across LINKnet turbine control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9905-969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.11 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14 x 11 x 4 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+24 VDC at 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e6 Channel (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response\u003c\/h3\u003e\n\u003cp\u003eThe 9905-969 module facilitates distributed analog signal collection, interfacing with the NetCon controller via a single twisted-pair communication trunk. The input channels are optimized for 4-20 mA sensor feedback, providing the necessary data for sequencing and monitoring tasks. In systems utilizing actuator loop feedback, the module translates field device current levels into digital packets, which are then processed by the NetCon controller's defined rate group. Consistent signal integrity is maintained through isolated network trunks, with each module configured via dual rotary switches to ensure accurate node addressing (1 to 60) within the LINKnet architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 9905-969 module be hot-swapped during active network communication?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed as a plug-in component for the LINKnet system. However, replace modules only when the trunk is powered down or when the system software configuration permits safe removal to prevent address conflict or communication bus instability.\u003c\/p\u003e\n\u003cp\u003eQ: How are network address conflicts avoided when installing multiple modules?\u003c\/p\u003e\n\u003cp\u003eA: Each module utilizes two rotary switches to set the node address. This address must correspond precisely with the configuration assigned within the MOE coder program to ensure data packets are correctly routed to the assigned channel rate group.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is securely mounted in the control cabinet. Maintain adequate spacing to allow for proper airflow within the -40 to 55 deg C operating range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressing:\u003c\/strong\u003e Before inserting the module, set the dual rotary switches to the address specified by the system integrator’s configuration file.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Wiring:\u003c\/strong\u003e Connect the module to the NetCon controller trunk using a single twisted-pair wire. Ensure terminations are tight to prevent intermittent data loss on the 277 VAC rated network line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Ground cable shields at the designated cabinet terminals to protect against common-mode noise, especially in environments where humidity reaches the 95% threshold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e After power-up, check the 2-line display for status indicators. Ensure the NetCon controller acknowledges the node before calibrating the 6 channels via the MOE coder program.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53002110402869,"sku":"9905-969","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/9905-969.png?v=1781506393","url":"https:\/\/www.5gplc.com\/products\/woodward-9905-969-linknet-6-channel-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}