{"product_id":"woodward-8440-1750-easygen-1000-genset-controller","title":"Woodward 8440-1750 easYgen-1000 Genset Controller","description":"\u003cp\u003eConfigured for generator set management and synchronization, the \u003cstrong\u003eWoodward 8440-1750\u003c\/strong\u003e (\u003cstrong\u003eeasYgen-1000\u003c\/strong\u003e Genset Controller) provides direct electrical execution of power monitoring and breaker control logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8440-1750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e219 mm x 171 mm x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6.5-40.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Frequency\u003c\/td\u003e\n\u003ctd\u003e40-70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response and Load Management\u003c\/h3\u003e\n\u003cp\u003eThe 8440-1750 utilizes FlexRange technology for RMS voltage sensing and integrates FlexApp configurations to manage breaker states in stand-by power applications. The unit monitors generator output against a set point range of 50 to 650,000 VAC. Operational integrity is dependent on maintaining surge voltage protection limits below 2.5 kV; exceeding this threshold can result in hardware damage and loss of control functionality. The controller includes an internal real-time clock backed by a battery with a six-year minimum service life, ensuring event logging (up to 300 entries) remains synchronized even during loss of primary power.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 8440-1750 support hot-swap of the terminal blocks during operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The unit contains 58 distinct terminals mapped to specific engine control functions. Hot-swapping is not supported; all power must be removed from the controller and engine interface before disconnecting or reconnecting terminal blocks to prevent transient voltage spikes.\u003c\/p\u003e\n\u003cp\u003eQ: Is the battery for the real-time clock user-replaceable?\u003c\/p\u003e\n\u003cp\u003eA: The battery is internal and designed for a six-year life cycle. Replacement requires opening the controller chassis, which should only be performed by authorized personnel to maintain the UL\/cUL and marine approval certifications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the controller in a panel cutout, ensuring the seal is compressed to maintain the desired ingress protection rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cabling for all sensor inputs. Ensure the controller ground terminal is connected to the cabinet earth bus using a low-impedance conductor to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Connections:\u003c\/strong\u003e Verify the tightening torque for all 58 terminals. Loose connections in the engine interface circuit will cause intermittent signal drops and potential erratic engine behavior.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Protection:\u003c\/strong\u003e Ensure external surge suppression is installed on AC sensing lines to keep incoming transients within the 2.5 kV rated limit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53005142753589,"sku":"8440-1750","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/8440-1750.png?v=1781590253","url":"https:\/\/www.5gplc.com\/products\/woodward-8440-1750-easygen-1000-genset-controller","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}