{"product_id":"woodward-8200-1302-graphical-hmi-operator-panel","title":"Woodward 8200-1302 Graphical HMI Operator Panel","description":"\u003cp\u003eConfigured for steam turbine management in 505D control platforms, the \u003cstrong\u003eWoodward 8200-1302\u003c\/strong\u003e (\u003cstrong\u003e8200-1302\u003c\/strong\u003e Operator Control Panel) provides direct physical\/electrical execution of turbine HMI interaction, parameter configuration, and process monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8200-1302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.4 in (LCD Screen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18-36 VDC (Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels (4-20 mA compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP-54 (Marine \/ ATEX Compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response\u003c\/h3\u003e\n\u003cp\u003eThe 8200-1302 serves as the primary graphical interface for Woodward 505D governors, managing the communication and command flow required for stable turbine regulation. To ensure a predictable actuator loop feedback response, the unit processes dual redundant speed inputs—accepting signals from magnetic pickup units (MPUs), eddy current probes, or proximity probes—to compute precise speed control setpoints. The interface manages dual speed and load dynamics, allowing for optimized governor response during transient loading or frequency dead-band adjustments. The integration of 8 configurable analog inputs and 20 discrete contact inputs allows the controller to synthesize operational data into 4-20 mA control outputs, ensuring that the governor maintains setpoint integrity even under fluctuating process steam conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 8200-1302 communicate with external systems via standard industrial protocols?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit utilizes integrated Modbus communication ports for data exchange with external host controllers, SCADA systems, or auxiliary HMIs.\u003c\/p\u003e\n\u003cp\u003eQ: Are the redundant speed inputs compatible with all probe types?\u003c\/p\u003e\n\u003cp\u003eA: The dual redundant speed inputs are designed to accept a variety of sensing technologies, including passive magnetic pickup units (MPUs) and active eddy current or proximity probes. Ensure the sensor signal levels are within the input range of the 505D platform during commissioning.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the HMI in a panel cutout, ensuring the seal maintains the IP-54 rated ingress protection. Adhere to the Marine\/ATEX compliance standards for physical clearance and grounding to prevent localized EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route 4-20 mA signal loops and contact inputs using shielded twisted-pair cabling. Separate these from high-power field cabling to avoid interference with the speed sensor acquisition circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Connect the unit to an isolated 18-36 VDC supply. Use proper surge protection to comply with EN 61000-6-2 electromagnetic immunity standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e After power-up, navigate to the calibration mode to verify the mapping of the 20 contact inputs and ensure the 8 analog inputs are correctly scaled for the turbine process variables. Confirm Modbus communication handshake before finalizing the configuration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53002319528245,"sku":"8200-1302","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/8200-1302.png?v=1781515164","url":"https:\/\/www.5gplc.com\/products\/woodward-8200-1302-graphical-hmi-operator-panel","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}