{"product_id":"woodward-5501-429-controller-module","title":"Woodward 5501-429 Controller Module","description":"\u003cp\u003eConfigured for proportional or integrating actuator control in MicroNet systems, the \u003cstrong\u003eWoodward 5501-429\u003c\/strong\u003e (\u003cstrong\u003e25mA Version\u003c\/strong\u003e Actuator Controller) provides direct electrical execution of dual-channel hydromechanical or pneumatic actuator management.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5501-429\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess than 2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.25 in x 9.75 in x 1 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 V at 0.5 A, +24 V at 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e25 mA (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Resistance\u003c\/td\u003e\n\u003ctd\u003e10\/30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Read back Tolerance\u003c\/td\u003e\n\u003ctd\u003e5 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response and Thermal Heat Sink Dissipation Profiles\u003c\/h3\u003e\n\u003cp\u003eThe 5501-429 utilizes model-based control to regulate actuator position via integrated LVDT or RVDT feedback loops. The module enforces strict actuator loop feedback response by monitoring excitation, feedback voltage, and driver current status, ensuring compliance with specified control setpoints. Internal diagnostics provide hardware-level fault detection, including CPU communication status and microcontroller operational integrity. The module is designed to operate within MicroNet chassis thermal limits; however, consistent adherence to airflow guidelines is required to maintain the module's thermal heat sink dissipation profiles during high-duty actuator modulation. Any deviation in current read back exceeding the 5% tolerance threshold triggers an internal alarm, signaling a potential feedback mismatch or actuator drive degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How can the front-panel LED be interpreted for system troubleshooting?\u003c\/p\u003e\n\u003cp\u003eA: A solid red LED indicates a loss of communication between the controller and the CPU module. A flashing red LED signifies an internal hardware error, necessitating immediate module replacement.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary feedback device compatibility requirements for this module?\u003c\/p\u003e\n\u003cp\u003eA: The 5501-429 supports one or two position feedback devices per channel, specifically LVDT or RVDT sensors, which are configured via the MicroNet control software to map position to the actuator demand.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Slide the module into the control chassis card guides and seat firmly into the motherboard connectors. Utilize the top and bottom extraction handles to ensure the connector pins are fully engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabling:\u003c\/strong\u003e Utilize a MicroNet low-density discrete cable for all module communications. Ensure signal shielding is maintained to ground to prevent noise injection into the LVDT\/RVDT feedback signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowering:\u003c\/strong\u003e Verify that the +5 V and +24 V power rails are within nominal tolerances before applying power to the module. Ensure the external power supply is capable of sustaining the 1 A current requirement on the 24 V rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e Following physical installation, confirm the module is recognized by the CPU via the system interface. If the red LED remains solid, verify the backplane ribbon cable integrity and CPU communication configuration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53005255475509,"sku":"5501-429","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5501-429.png?v=1781595077","url":"https:\/\/www.5gplc.com\/products\/woodward-5501-429-controller-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}