{"product_id":"woodward-5501-367-micronet-simplex-lv-discrete-ftm","title":"Woodward 5501-367 MicroNet Simplex LV Discrete FTM","description":"\u003cp\u003eConfigured for discrete and analog signal interface in MicroNet control platforms, the \u003cstrong\u003eWoodward 5501-367\u003c\/strong\u003e (\u003cstrong\u003e5501-367\u003c\/strong\u003e Simplex LV Discrete FTM) provides direct physical\/electrical execution of signal conditioning for monitoring and control circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5501-367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.11 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.75 x 14.625 x 5.375 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e14 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e18-32 VDC (27.4 A max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal to Actuator\u003c\/td\u003e\n\u003ctd\u003e0-200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Isolation\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms (0-60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHarmonic Distortion Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 5501-367 module incorporates specialized signal conditioning to maintain loop integrity when driving inductive loads such as solenoids and relays. The architecture utilizes filtering stages to achieve harmonic distortion suppression, ensuring that switching noise generated by the output channels does not propagate into the sensitive control logic. Furthermore, the 1000 Vrms network isolation barrier protects the internal processor bus from transient spikes originating on the field-side wiring, facilitating a stable actuator loop feedback response. This isolation is critical for maintaining signal fidelity across the four input channels, which support a mix of switch contact, 4-20 mA current loop, and voltage-level signals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the four output channels independently capable of driving high-current loads?\u003c\/p\u003e\n\u003cp\u003eA: Yes, each of the four output channels can source up to 2 A at 24 VDC. When operating multiple channels simultaneously, ensure the total load does not exceed the aggregate power supply capacity to prevent thermal degradation.\u003c\/p\u003e\n\u003cp\u003eQ: Is the FTM compatible with hot-swapping procedures?\u003c\/p\u003e\n\u003cp\u003eA: The module is not designed for hot-swapping while the control system is powered. All power must be isolated from the 18-32 VDC input terminals before removal or insertion to prevent arcing and damage to the backplane communication contacts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the FTM in a clean, ventilated enclosure. The 8.75 x 14.625 x 5.375 inch footprint requires adequate clearance for cable management and heat dissipation at the rated 55 deg C operating temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Separate low-voltage signal wiring (4-20 mA) from high-current output lines (24 VDC, 2 A) to mitigate crosstalk. Use shielded cables for all input channels and terminate shields at the designated chassis grounding point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connection:\u003c\/strong\u003e Verify the 18-32 VDC supply polarity before landing wires on the power input terminals. The use of an external overcurrent protection device sized for the 27.4 A maximum input rating is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eValidation:\u003c\/strong\u003e During commissioning, verify that the input channels are correctly scaled for the specific sensor type (voltage vs. current). Test each output channel individually to confirm correct actuation of field devices before enabling the automated control sequence.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":53002190422325,"sku":"5501-367","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5501-367.png?v=1781511593","url":"https:\/\/www.5gplc.com\/products\/woodward-5501-367-micronet-simplex-lv-discrete-ftm","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}