{"product_id":"ve4036p2-emerson-redundant-m-series-serial-interface-card","title":"VE4036P2 | Emerson | Redundant M-Series Serial Interface Card","description":"\u003cp\u003eConfigured for serial communication bridge execution in DeltaV control networks, the \u003cstrong\u003eEmerson VE4036P2\u003c\/strong\u003e (\u003cstrong\u003eVE4036P2\u003c\/strong\u003e Serial Interface Card) provides direct physical\/electrical connectivity for M-Series I\/O subsystems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4036P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVE4036P2\u003c\/strong\u003e incorporates advanced channel-to-channel isolation to ensure that serial data paths remain protected from common-mode electrical transients within the field wiring environment. In redundant M-Series architectures, this module supports seamless failover logic, ensuring that serial communication with peripheral devices is maintained in the event of a primary card fault. The module is engineered for integration with FOUNDATION Fieldbus or Profibus PA gateways, facilitating deterministic data exchange across the DCS backbone. Cold junction compensation (CJC) is managed through the associated baseplate terminal interface for precise signal reference in multi-node configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping during active serial communication?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping. When the card is removed from a redundant pair, the standby module assumes communication duties without manual intervention, provided the configuration is set for automatic failover.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific termination requirements for the serial interface?\u003c\/p\u003e\n\u003cp\u003eA: Yes, ensure that the serial data lines are correctly terminated according to the specific protocol standard (e.g., RS-485 or RS-232) to prevent signal reflections. Use twisted-pair, shielded cabling and terminate the shield at the cabinet ground bus to minimize electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarrier Mounting\u003c\/strong\u003e: Insert the module into the designated M-Series carrier. Verify that the guide pins are aligned and the module is fully seated to engage the backplane bus connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cabling\u003c\/strong\u003e: Connect field serial devices to the terminal blocks on the I\/O baseplate. Maintain consistent wire gauge and torque specifications for terminal screw connections to ensure secure physical contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Terminate cable shields at the designated grounding points on the baseplate. Avoid routing serial communication lines alongside high-voltage power cables to mitigate crosstalk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Use the DeltaV hardware configuration utility to assign the port address and communication parameters to the module. Perform a communication health check to verify proper handshake with the serial field device.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52933795676469,"sku":"VE4036P2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VE4006P2_bd058b5e-0aa9-4348-9e5c-65d08f196d7c.png?v=1779949339","url":"https:\/\/www.5gplc.com\/products\/ve4036p2-emerson-redundant-m-series-serial-interface-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}