{"product_id":"ve4022-m-series-profibus-dp-interface-card-emerson","title":"VE4022 M-Series Profibus DP Interface Card | Emerson","description":"\u003cp\u003eConfigured for fieldbus integration in DeltaV control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE4022\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eVE4022\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProfibus DP Interface Card) provides direct physical\/electrical execution of deterministic Profibus DP communication across M-Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE4022\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.91 kg (2.00 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM-Series module form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem-powered via backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnectivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfibus DP protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSimplex termination block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: Profibus DP Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe VE4022 serves as a dedicated communication gateway, facilitating the integration of Profibus DP-compliant field devices into the DeltaV control architecture. This card manages the deterministic cyclic exchange of process data and allows for the acyclic parameterization of field instruments. The internal bus interface is isolated from the field communication port, ensuring that potential ground loops or electrical surges at the Profibus network segment do not interfere with the controller's backplane communication.  The module supports high-speed baud rate synchronization and enforces protocol-compliant bus timing, maintaining strict master-slave communication cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the VE4022 card support redundant operation?\u003c\/p\u003e\n\u003cp\u003eA: The VE4022 is provided with a simplex termination block, intended for non-redundant Profibus DP master configurations. For redundant fieldbus requirements, a dual-redundant card and carrier configuration must be utilized.\u003c\/p\u003e\n\u003cp\u003eQ: Is the Profibus DP port electrically isolated?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The Profibus port on the VE4022 is galvanically isolated from the M-Series backplane. This isolation is mandatory to protect the internal controller logic from electrical noise prevalent in extended Profibus fieldbus segments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the VE4022 into the designated slot on the M-Series I\/O carrier. Ensure the simplex termination block is fully seated to maintain the integrity of the signal path and the mechanical grounding of the module housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProfibus DP networks require active termination at both ends of the physical segment. Ensure that the bus segments connected to the VE4022 are terminated according to the Profibus standard (using 220 Ohm bias resistors) to prevent signal reflection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate the Profibus cable shield at the cabinet entry point using a low-impedance grounding bar. Continuous shielding is mandatory to maintain data integrity across the high-speed bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter installation, verify the network configuration in the DeltaV engineering station and perform a diagnostic scan of the field devices to confirm communication status and the absence of frame errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924230664501,"sku":"VE4022","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VE4022.png?v=1779780002","url":"https:\/\/www.5gplc.com\/products\/ve4022-m-series-profibus-dp-interface-card-emerson","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}