{"product_id":"ve4003s2b3-deltav-m-series-analog-input-termination-block-emerson","title":"VE4003S2B3 DeltaV M-Series Analog Input Termination Block | Emerson","description":"\u003cp\u003eConfigured for analog signal acquisition in DeltaV I\/O subsystems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE4003S2B3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eVE4003S2B3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input Termination Block) provides direct physical\/electrical execution of 8-channel 4-20 mA signal interfacing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE4003S2B3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard M-series terminal block footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive signal distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA (4-wire compatible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe VE4003S2B3 termination block is engineered to maintain signal integrity through systematic channel-to-channel isolation on the DeltaV I\/O carrier. This physical architecture ensures that high-voltage transients or field-side faults in one channel do not propagate across the common terminal block assembly, protecting both the I\/O card and the controller backplane. The block accommodates 24 VDC field power distribution, with internal routing paths optimized to minimize impedance while maintaining strict dielectric separation between discrete or analog signal paths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does this termination block support 2-wire transmitter configurations?\u003c\/p\u003e\n\u003cp\u003eA: The VE4003S2B3 is specifically designed for 4-wire analog input applications where the transmitter is powered by an external source. Attempting to use this block for 2-wire loop-powered transmitters may result in signal errors or lack of loop power.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with all M-series analog input cards?\u003c\/p\u003e\n\u003cp\u003eA: The VE4003S2B3 is designed for use with compatible M-series analog input cards. Ensure that the I\/O card configuration and the specific card hardware support the 4-wire, 8-channel input interface before installation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeat the terminal block onto the M-series I\/O carrier. Verify that the mechanical keying pins are aligned with the corresponding I\/O card slot to prevent improper mating and potential electrical shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate field wiring according to the loop diagram for 4-wire transmitters. Use shielded twisted pair cabling to maintain signal noise immunity. Ensure that shields are tied to the designated cabinet grounding lug on the carrier to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTighten terminal screws to the manufacturer-specified torque to ensure low-resistance contact and prevent wire pull-out under vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the field power voltage at the transmitter matches the 24 VDC requirements before establishing loop continuity. Ensure no foreign voltage is present on the signal lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924153069877,"sku":"VE4003S2B3","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VE4002S1T2B6_04ee066e-823f-4409-be3a-9e59a769c7e9.png?v=1779777703","url":"https:\/\/www.5gplc.com\/products\/ve4003s2b3-deltav-m-series-analog-input-termination-block-emerson","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}