{"product_id":"ua-c326-ae01-hiee401481r1-abb-analog-digital-i-o-card","title":"UA C326 AE01 HIEE401481R1 | ABB | Analog\/Digital I\/O Card","description":"\u003cp\u003eConfigured for high-density signal acquisition and discrete load actuation in industrial automation networks, the \u003cstrong\u003eABB UA C326 AE01 HIEE401481R1\u003c\/strong\u003e (\u003cstrong\u003eUA C326 AE01\u003c\/strong\u003e) Analog\/Digital I\/O Card provides direct physical\/electrical execution across hybrid field instrument channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUA C326 AE01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eHIEE401481R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e15.0 cm x 5.0 cm x 2.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane \/ Field circuit powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eMixed Analog \/ Digital I\/O Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, Modbus, Profibus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks \u0026amp; Backplane Bus Velocity\u003c\/h3\u003e\n\u003cp\u003eThe UA C326 AE01 HIEE401481R1 module interfaces directly with controller backplane buses to maintain deterministic signal processing across Modbus, Profibus, and Ethernet communications. Internal circuitry handles high-voltage AC inputs alongside 24 VDC outputs rated up to 10 A without degrading backplane bus communication velocity. Onboard firmware flash compatibility routines manage protocol translation latencies, ensuring real-time execution across industrial control platforms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input and output voltage levels are supported by the UA C326 AE01 HIEE401481R1 card?\u003c\/p\u003e\n\u003cp\u003eA: The card accepts wide-range AC input signals from 24 to 240 VAC and provides discrete DC switching output channels rated at 24 VDC with a maximum load capacity of 10 A.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication bus protocols are compatible with this I\/O module?\u003c\/p\u003e\n\u003cp\u003eA: The module supports integration into Modbus, Profibus, and Ethernet industrial network architectures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eModule Insertion: Ensure main rack power is shut down before inserting or removing the card to prevent backplane pin electrical arcing.\u003c\/li\u003e\n\u003cli\u003eField Wiring Isolation: Route high-voltage AC input lines (24-240 VAC) in separate conduit channels from low-voltage 24 VDC output wiring to prevent transient coupling.\u003c\/li\u003e\n\u003cli\u003eCable Shielding: Connect all communication network cable shields (Profibus\/Ethernet) directly to the cabinet functional earth (FE) terminal using low-impedance grounding clamps.\u003c\/li\u003e\n\u003cli\u003eThermal Clearance: Maintain standard vertical spacing around the card edge connectors to allow adequate convective cooling inside the enclosure.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53227700748597,"sku":"UA C326 AE01 HIEE401481R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/UAC326AE01HIEE401481R1.png?v=1785397756","url":"https:\/\/www.5gplc.com\/products\/ua-c326-ae01-hiee401481r1-abb-analog-digital-i-o-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}