{"product_id":"tsx-det-3242-schneider-digital-input-module-for-modicon-tsx-micro","title":"TSX-DET-3242 | Schneider Digital Input Module for Modicon TSX Micro","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider TSX-DET-3242 Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input module designed for\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eModicon TSX Micro\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eprogrammable logic controllers (PLCs). It provides high-density signal acquisition for control systems, enabling accurate monitoring of field inputs such as switches, sensors, and contact devices. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSX-DET-3242\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures stable operation with reliable isolation and high signal integrity, making it an excellent choice for industrial automation and process control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSchneider Electric \/ Telemecanique\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSX-DET-3242\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModicon TSX Micro PLCs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 channels (24V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSink or source type, configurable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19–30 V DC (nominal 24 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 mA per point (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1–3 ms typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical isolation between channels and bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLED per channel for signal status monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 150 mA from the PLC backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-25°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e130 mm × 100 mm × 60 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.45 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiscrete input monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein production automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePLC-based machine control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring fast and stable signal response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing and assembly lines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith multiple sensor connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing Modicon TSX Micro architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which PLCs are compatible with the TSX-DET-3242 module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is compatible with Modicon TSX Micro PLCs and controllers that support the TSX bus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the input type be configured for both sink and source devices?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the module supports both input configurations, offering flexibility for different wiring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the TSX-DET-3242 provide input isolation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, optical isolation protects the PLC backplane and ensures stable signal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Are LED indicators available for diagnostics?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, each channel includes an LED status indicator to simplify signal troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52321912488245,"sku":"TSXDET3242","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TSXDET3242.jpg?v=1770946619","url":"https:\/\/www.5gplc.com\/products\/tsx-det-3242-schneider-digital-input-module-for-modicon-tsx-micro","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}