{"product_id":"triconex-3000110-380-2553-8-24v-digital-input-terminal-assembly","title":"TRICONEX 3000110-380 2553-8 24V Digital Input Terminal Assembly","description":"\u003cp\u003eConfigured for high-integrity safety-instrumented system applications, the \u003cstrong\u003eTRICONEX 3000110-380\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3000110-380\u003c\/strong\u003e 24V Digital Input Terminal Assembly, provides direct physical\/electrical execution. The hardware manages field-side discrete signal termination for 24 V digital input loops, routing sensor inputs across redundant termination architectures within Triconex safety instrumented platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3000110-380 \/ 2553-8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTRICONEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Manufacturing Facility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.00 lbs (3.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Termination Panel Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Range (0 deg C to 60 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Termination Panel (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e24 V Digital Input Terminal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eTriconex Safety Instrumented System (SIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003e24 V Discrete Input Field Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Triple Modular Redundancy Architecture\u003c\/h3\u003e\n\u003cp\u003eEngineered for high-integrity safety applications, this terminal assembly supports SIL3 certification compliance by routing redundant discrete input loops across triple modular redundancy (TMR) 2oo3 architecture legs. Internal circuit layouts incorporate rigorous galvanic isolation and fail-safe state execution pathways, ensuring that single-point faults or field-side wiring transients do not compromise emergency shutdown logic or trigger spurious trips within safety-critical loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3000110-380 termination assembly require external power distribution for field sensors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, external 24 V power supplies must be routed through the designated panel terminals to energize field-side discrete input devices connected to the safety system.\u003c\/p\u003e\n\u003cp\u003eQ: Can interface cables be disconnected from the terminal assembly while the Triconex system is energized?\u003c\/p\u003e\n\u003cp\u003eA: Uncoupling pre-formed inter-cabinet or module interface cables under live operating conditions is restricted to prevent open-circuit faults, signal spikes, or momentary channel degradation on active safety loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the termination panel securely onto standard DIN rails or structural backplane standoffs inside an approved safety-rated instrumentation cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure all field signal shield drain wires are terminated continuously to the integrated ground busbar to maintain noise immunity against electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that incoming loop voltages and signal types strictly match system configuration requirements prior to energizing field circuits.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate physical separation between safety-instrumented signal wiring and high-voltage power conduits to prevent cross-regulated attenuation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":67720266547509,"sku":"3000110-380","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/3000110-380_Cocoai.png?v=1792134053","url":"https:\/\/www.5gplc.com\/products\/triconex-3000110-380-2553-8-24v-digital-input-terminal-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}