{"product_id":"tp-zsbhm2-100-honeywell-upgrade-kit","title":"TP-ZSBHM2-100 Honeywell Upgrade Kit","description":"\u003cp\u003eConfigured for hardware migration and dual-drive system expansion in TDC 3000 process platforms, the \u003cstrong\u003eHoneywell TP-ZSBHM2-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTP-ZSBHM2-100\u003c\/strong\u003e UPG KIT, HM TO SBHMW\/TWODRIVES, provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTP-ZSBHM2-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard TDC 3000 chassis board dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC backplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHistory Module Upgrade Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 Process Manager \/ LCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle Board History Module with Dual Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Protocol\u003c\/td\u003e\n\u003ctd\u003eLocal Control Network (LCN) backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe upgrade kit interfaces with the Local Control Network (LCN) backplane to maintain deterministic data archiving across 4-20 mA HART loop protocol field inputs and process variable trends. Built-in channel-to-channel isolation on backplane power rails protects mass storage controllers from electrical noise and voltage spikes generated during drive access cycles. Passive backplane filtering preserves high signal-to-noise ratios during continuous multi-channel history collection and retrieval operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary hardware transition does the TP-ZSBHM2-100 kit perform?\u003c\/p\u003e\n\u003cp\u003eA: The kit upgrades standard legacy TDC 3000 History Modules (HM) to Single Board History Module (SBHM) architecture with dual-drive storage capability.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required for the TP-ZSBHM2-100 upgrade boards?\u003c\/p\u003e\n\u003cp\u003eA: No, power is drawn directly from the internal 24 VDC \/ 5 VDC system backplane lines of the TDC 3000 card cage.\u003c\/p\u003e\n\u003cp\u003eQ: Can the dual drives in this configuration be hot-swapped during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Drive replacement requires following Honeywell TDC 3000 LCN offline\/online maintenance protocols to prevent history database corruption or bus errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower down the targeted card cage slot and observe full ESD grounding procedures before inserting the SBHM upgrade board assembly.\u003c\/li\u003e\n\u003cli\u003eVerify that backplane connector pins are straight and clean prior to sliding the board into the mounting rails.\u003c\/li\u003e\n\u003cli\u003eEnsure all drive ribbon cables and power harnesses maintain a minimum of 5-thread mechanical engagement on retaining hardware where applicable.\u003c\/li\u003e\n\u003cli\u003eBond the chassis ground strap to the main protective earth (PE) bus to ensure noise immunity across disk controller data lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53631301878069,"sku":"TP-ZSBHM2-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/K2LCN-851402615-800_Cocoai_50ea037e-69b3-4bd8-a424-f7b9ed89c214.png?v=1790133578","url":"https:\/\/www.5gplc.com\/products\/tp-zsbhm2-100-honeywell-upgrade-kit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}