{"product_id":"tl-q5mc1-inductive-proximity-sensors-honeywell","title":"TL-Q5MC1 Inductive Proximity Sensors | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TL-Q5MC1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTL-Q5MC1\u003c\/strong\u003e Inductive Proximity Sensors, operates as a dedicated hardware component for non-contact metallic target detection within automated industrial sensing loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTL-Q5MC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCurrent consumption \u0026lt;= 10 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10-30 VDC (Rated: 12-24 VDC, ripple \u0026lt; 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNPN open collector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003eNormally Open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Current\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 V at 50 mA (2 m cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Frequency\u003c\/td\u003e\n\u003ctd\u003e500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Circuits\u003c\/td\u003e\n\u003ctd\u003eReverse polarity protection, surge suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eWhen integrated alongside analog field instrumentation, the TL-Q5MC1 digital switching signals pass to DCS discrete input channels without inducing switching noise into adjacent 4-20 mA HART loop protocol lines. Internal surge suppression network components absorb transient voltage spikes during high-frequency actuation up to 500 Hz.\u003c\/p\u003e\n\u003cp\u003eMaintaining proper channel-to-channel isolation on the receiving I\/O termination block ensures that NPN open collector switching currents up to 50 mA do not alter analog loop current references or disrupt low-level digital telecommunication layers across neighboring terminal blocks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum switching frequency supported by the TL-Q5MC1 proximity sensor?\u003c\/p\u003e\n\u003cp\u003eA: The sensor operates at a maximum response frequency of 500 Hz with a maximum response time of 2 ms.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TL-Q5MC1 include internal protection against reversed supply wiring?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the sensor includes built-in reverse polarity protection and surge suppression circuitry to prevent internal component damage.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical load limitations apply to the NPN output stage?\u003c\/p\u003e\n\u003cp\u003eA: The NPN open collector output handles a maximum switching current of 50 mA with a maximum load voltage of 30 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify input voltage supply limits are within 10-30 VDC with ripple below 10% before applying system power.\u003c\/li\u003e\n\u003cli\u003eEnsure target metal mass meets standard sensing face alignment requirements to guarantee full 500 Hz switching capability.\u003c\/li\u003e\n\u003cli\u003eConnect sensor cable shielding to the designated earth ground terminal in the junction box to prevent EMI coupling.\u003c\/li\u003e\n\u003cli\u003eMaintain physical isolation between sensor signal cabling and high-power AC motor or drive wiring in cabinet channels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53197407486261,"sku":"TL-Q5MC1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TL-Q5MC1.png?v=1784704724","url":"https:\/\/www.5gplc.com\/products\/tl-q5mc1-inductive-proximity-sensors-honeywell","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}