{"product_id":"tk527v030-3bsc950004r1-abb-interface-cable","title":"TK527V030 3BSC950004R1 ABB Interface Cable","description":"\u003cp\u003eConfigured for serial program downloading in Advant Master architectures, the \u003cstrong\u003eABB TK527V030 3BSC950004R1\u003c\/strong\u003e (\u003cstrong\u003eTK527V030\u003c\/strong\u003e Interface Cable) provides direct physical\/electrical execution. The prefabricated assembly establishes a point-to-point physical connection between an external PC configuration node and localized fieldbus communication modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK527V030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3BSC950004R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.295 kg net\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3000 mm x 6.5 mm x 6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eDE9 pin to DE9 socket (DB9 Male to DB9 Female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Hardware Interfaces\u003c\/td\u003e\n\u003ctd\u003eCI801, CI810, CI820, CI830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive physical conductor assembly (Zero draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eExempt from RoHS 2011\/65\/EU scope per Article 2(4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrefabricated Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe TK527V030 acts as a dedicated physical bridge to update system parameters without degrading active backplane bus communication velocity parameters. The core pinout configuration matches the voltage signaling demands required during software flash compatibility updates. When mapped alongside Profinet \/ EtherNet\/IP deterministic networks, this cable delivers direct serial payload delivery to the target communication interfaces, eliminating signal reflection and ensuring data block integrity remains within standardized timing tolerances during local engineering firmware modifications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are additional hardware components required when using the TK527V030 to interface with a CI801 module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Software downloads directly targeting the CI801 fieldbus communication module require the use of an auxiliary TK212A adapter assembly in addition to the base TK527V030 line.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be hot-plugged while the master control system is online and executing cyclic tasks?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Because the TK527V030 is a passive cable assembly, connecting the DE9 interfaces does not cause configuration dropouts on adjacent active slots, provided the configuration software on the PC is executed in standard download mode.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Pin Orientation:\u003c\/strong\u003e Align the DE9 pins and sockets exactly before pushing the plug assemblies together to prevent the distortion or breaking of internal physical conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Screw Retention:\u003c\/strong\u003e Secure both integrated thumb fasteners on the DE9 connector shells to prevent signal loss caused by localized plant vibration or stress on the 3 m cable run.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation from Power Sources:\u003c\/strong\u003e Route the 3 m length clear of high-voltage AC\/DC lines and motor drive paths to isolate the internal serial data wires from external electromagnetic coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53109177090357,"sku":"TK527V030 3BSC950004R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TK527V0303BSC950004R1.png?v=1783591388","url":"https:\/\/www.5gplc.com\/products\/tk527v030-3bsc950004r1-abb-interface-cable","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}