{"product_id":"tk-ccr014-honeywell-experion-pks-control-module","title":"TK-CCR014 Honeywell Experion PKS Control Module","description":"\u003cp\u003eConfigured for high-density I\/O integration and serial bus routing in Honeywell Experion PKS networks, the \u003cstrong\u003eHoneywell TK-CCR014 97332573 A01\u003c\/strong\u003e (\u003cstrong\u003eTK-CCR014\u003c\/strong\u003e Multifunctional Control Module) provides direct physical\/electrical execution. Cataloged under part number 97332573-A01 with firmware revision 10.006, it processes 4 analog inputs, 4 analog outputs, 8 digital inputs, and 8 digital outputs while executing redundant network communication across serial RS-232 and RS-485 interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTK-CCR014 (PN: 97332573-A01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndustrial Standard Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e115 mm x 76 mm x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 W typical, 35 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor \u0026amp; Memory\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC (800 MHz), 512 MB RAM, 1 GB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Channels\u003c\/td\u003e\n\u003ctd\u003e4 AI, 4 AO, 8 DI, 8 DO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-232, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Revision\u003c\/td\u003e\n\u003ctd\u003eRev 10.006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; DCS Integration\u003c\/h3\u003e\n\u003cp\u003eThe TK-CCR014 control module incorporates channel-to-channel isolation barriers to decouple analog field instrumentation circuits from internal 32-bit RISC processing logic. This electrical isolation prevents ground loop potential shifts and suppresses common-mode noise during analog-to-digital conversions on incoming field channels. The module maintains deterministic signal transfer across serial RS-485 networks while processing co-located 4-20 mA HART loop protocol instruments linked to central Honeywell Experion PKS nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the TK-CCR014 module require external power supplies for its field-side logic operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit requires a dedicated nominal 24 VDC external supply, drawing 25 W under typical load and up to 35 W maximum.\u003c\/p\u003e\n\u003cp\u003eQ: How are serial network interfaces physically configured on the TK-CCR014?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates built-in RS-232 and RS-485 communication interfaces to handle point-to-point and multi-drop serial bus protocols within distributed control topologies.\u003c\/p\u003e\n\u003cp\u003eQ: What is the firmware compatibility requirement for replacing a TK-CCR014 unit?\u003c\/p\u003e\n\u003cp\u003eA: The replacement unit must match the host system node configuration, running firmware revision 10.006 (or compatible flash releases) on its 1 GB flash memory.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eIsolate the 24 VDC power source before mounting or wiring the TK-CCR014 module inside the control cabinet.\u003c\/li\u003e\n\u003cli\u003eSnap the enclosure onto a standard DIN rail or panel surface, maintaining space surrounding the IP20 housing for thermal convection.\u003c\/li\u003e\n\u003cli\u003eGround all RS-485 and analog input cable shields to the main cabinet ground bar to maintain noise immunity.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring strictly according to terminal pin assignments for the 4 AI, 4 AO, 8 DI, and 8 DO channels before restoring power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53599401312565,"sku":"TK-CCR014 97332573-A01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TK-CCR01497332573-A01_Cocoai.png?v=1789615788","url":"https:\/\/www.5gplc.com\/products\/tk-ccr014-honeywell-experion-pks-control-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}