{"product_id":"t8800-ics-triplex-digital-input-field-termination-assemblies","title":"T8800 ICS Triplex Digital Input Field Termination Assemblies","description":"\u003cp\u003eThe \u003cstrong\u003eICS Triplex T8800\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eT8800\u003c\/strong\u003e (1092330000) Digital Input Field Termination Assembly, operates as a dedicated hardware component for 40-channel field signal conditioning within ICS Triplex Trusted TMR platforms. Serving as the primary physical interface between 2-wire digital field devices and the Trusted TMR 24 Vdc Digital Input Module T8403, this unit processes discrete 24 VDC voltage states across an operating temperature range of -20 to 60 deg C (-4 to 140 deg F).\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8800 (1092330000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 50 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C (-4 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Line Conditioning (Field Bus Dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e40 input channels per FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus, TCP\/IP, EtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e2 GB RAM, 16 GB Flash Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection\u003c\/td\u003e\n\u003ctd\u003eIndustry-standard 2-wire field device connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eTrusted TMR 24 Vdc Digital Input Module T8403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy and Fault Isolation\u003c\/h3\u003e\n\u003cp\u003eThe ICS Triplex T8800 field termination assembly integrates directly into triple modular redundancy (TMR) 2oo3 architecture designs required for SIL3 certification compliance. Galvanic isolation between field loops, chassis ground, and system backplane circuitry suppresses transverse-mode noise and ground potential shifts across all 40 digital input channels. In the event of field wiring fault conditions or sensor signal disruption, the assembly maintains signal routing integrity to ensure uncorrupted state data reaching the T8403 module for fail-safe state execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the T8800 field termination assembly interface with the T8403 Digital Input Module?\u003c\/p\u003e\n\u003cp\u003eA: The T8800 connects 2-wire 24 VDC field sensors directly to dedicated terminal blocks, routing conditioned parallel digital inputs directly into the T8403 TMR input module connector header.\u003c\/p\u003e\n\u003cp\u003eQ: Can the T8800 FTA withstand direct exposure to dust and liquid in harsh industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the T8800 features a rugged stainless steel enclosure engineered and certified to an IP67 ingress protection rating.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the T8800 assembly onto a standard 35 mm DIN rail inside the enclosure cabinet and ensure the grounding latch locks firmly onto the rail.\u003c\/li\u003e\n\u003cli\u003eTerminate 2-wire field device leads into designated input channel screw terminals, maintaining strict polarity for 24 VDC loops.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring separate from high-voltage AC lines to minimize electromagnetic interference, observing a minimum separation distance of 200 mm.\u003c\/li\u003e\n\u003cli\u003eSecure multi-core interface cabling between the T8800 FTA board and the T8403 TMR Digital Input Module, ensuring cable retention latches are fully engaged.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":53407034245429,"sku":"T8800 1092330000","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/T8800.png?v=1787732850","url":"https:\/\/www.5gplc.com\/products\/t8800-ics-triplex-digital-input-field-termination-assemblies","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}