{"product_id":"sdo-0824-cc-v1-3-honeywell-safe-digital-output-module","title":"SDO-0824 CC V1.3 Honeywell | Safe Digital Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell SDO-0824 CC V1.3\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSDO-0824\u003c\/strong\u003e Safe Digital Output Module, operates as a dedicated hardware component for safety-critical actuator execution and discrete control signal driving within Honeywell Safety Manager and Fail Safe Controller (FSC) platforms. Providing 8 galvanically isolated digital output channels rated for 24 VDC load switching, the unit directly commands field devices such as solenoid valves, interlock relays, and visual alarms. The module incorporates internal diagnostic testing logic to continuously verify output switch integrity without interrupting active process safety loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSDO-0824 CC V1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4 HP, 3U standard rack slot profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC field load powered \/ 5 VDC logic bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafe Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 discrete output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FSC platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe SDO-0824 CC V1.3 utilizes high-density optical and galvanic channel-to-channel isolation barriers to separate internal microprocessor logic from high-current field loads. While adjacent field transmitters operate via 4-20 mA HART loop protocol lines inside shared cabinet raceways, the SDO-0824 output stage suppresses inductive kickback and voltage spikes caused by solenoid coil de-energization. This structural noise decoupling prevents high-frequency electrical switching transients from bleeding onto adjacent analog measurement channels or corrupting central system bus traffic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can individual output channels be replaced or serviced while the module remains active?\u003c\/p\u003e\n\u003cp\u003eA: Field load wiring connects via an external field termination assembly, allowing individual channel field loops to be isolated or serviced without removing the main SDO-0824 module from the subrack.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle short circuits on field output lines?\u003c\/p\u003e\n\u003cp\u003eA: Onboard current-limiting diagnostics detect short-circuit conditions on individual channels and transition the affected output to a fail-safe de-energized state while preserving active operation on remaining channels.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eAlign the 4 HP, 3U subrack card guide rails with the module top and bottom edges, pushing the assembly straight until the backplane connectors seat completely.\u003c\/li\u003e\n\u003cli\u003eFasten the captive retaining screws on the front panel to secure the card and ensure functional frame earth bonding.\u003c\/li\u003e\n\u003cli\u003eRoute 24 VDC output load conductors through dedicated cabinet wireways, maintaining separation from high-voltage AC cables and sensitive low-level analog signal paths.\u003c\/li\u003e\n\u003cli\u003eConfirm that total continuous output current across all 8 channels does not exceed maximum cabinet power supply thermal and amperage dissipation limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53625548800309,"sku":"SDO-0824 CC V1.3","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FS-SDO-824_fc138dfb-9ad3-430d-af9e-8f6e7be8586a.png?v=1790049476","url":"https:\/\/www.5gplc.com\/products\/sdo-0824-cc-v1-3-honeywell-safe-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}