{"product_id":"schneider-electric-tsxpsy2600m-modicon-premium-power-supply-module","title":"Schneider Electric TSXPSY2600M Modicon Premium Power Supply Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric TSXPSY2600M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-stability power for the Modicon Premium automation platform. This module converts wide-range AC input (100V to 240V) into regulated 5V DC and 24V DC voltages to energize the PLC backplane, internal processors, and field sensors. It features a standard module format that integrates directly into the Premium rack, ensuring efficient energy distribution with minimal thermal loss. We supply this power supply as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory-sealed packaging, maintaining the highest standard for system integrity and uptime.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe TSXPSY2600M delivers 26W of total secondary power with dedicated outputs for both logic and field-side devices.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100...240 V AC (Operational range: 85...264 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Frequency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50\/60 Hz (Limits: 47…63 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Power (Total):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e26 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Current Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* 5 A at 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e0.5 A at 24 V DC (Sensor supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0.6 A at 24 V DC (Relay supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal 4A time-delayed fuse (5 x 20 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOverload, overvoltage, and short-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImmunity to Microbreaks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2000 V primary\/earth and primary\/secondary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.12 lb (0.51 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 to 140 °F (0 to 60 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes three distinct LED indicators to provide real-time status. A green \"OK\" LED confirms the presence of internal voltages, a second green LED monitors sensor voltage (24V), and a red \"BAT\" LED alerts operators to battery faults. This allows technicians to identify power or backup failures without opening the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResilience to Power Fluctuations:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TSXPSY2600M includes an immunity buffer that handles microbreaks up to 10 ms. This feature prevents unnecessary system resets during momentary voltage dips common in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecondary Circuit Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in overvoltage and short-circuit protection for the secondary circuit safeguards sensitive processor and I\/O modules. If a field-side short occurs, the power supply isolates the fault, preventing catastrophic damage to the entire PLC rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtensive Marine and Industrial Certifications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module carries multiple certifications including ABS, BV, DNV, GL, and LR. These approvals ensure the unit operates reliably under the high-vibration and saline conditions found in maritime and offshore applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal AC Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe wide input range (85...264 V AC) eliminates the need for external step-down transformers in global facilities. This flexibility simplifies spare parts management for international organizations operating across different regional power grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the internal fuse if it blows?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module contains a standard 4A, 5 x 20 mm time-delayed fuse in the primary circuit. However, a blown fuse often indicates an underlying primary overvoltage or internal fault; always investigate the source of the failure before replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the 24V DC relay power supply output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe TSXPSY2600M provides a dedicated 0.6 A output specifically for relay power. This separates the high-frequency switching noise of mechanical relays from the 0.5 A sensor supply, ensuring cleaner signals for sensitive analog or digital inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSchneider Electric recommends powering down the rack before removing or installing power supply modules to prevent electrical arcing and to ensure the backplane initializes correctly upon restart.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know this is a brand new unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee every TSXPSY2600M is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. The unit ships in its original\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52484143055157,"sku":"TSXPSY2600M","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TSXPSY2600M.jpg?v=1774506526","url":"https:\/\/www.5gplc.com\/products\/schneider-electric-tsxpsy2600m-modicon-premium-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}