{"product_id":"schneider-electric-tsxaey1600-modicon-premium-analog-input-module","title":"Schneider Electric TSXAEY1600 Modicon Premium Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eTSXAEY1600 \u003c\/strong\u003eprocesses high-level analog current and voltage signals within the Modicon Premium automation platform. This high-density 16-channel analog input module decodes standard process variables from field instruments, including pressure transmitters, temperature sensors, flow meters, and variable speed drives. By hosting multi-range software configurations per channel and providing high galvanic isolation, this module serves as the primary data acquisition bridge for chemical manufacturing plants, water treatment facilities, and complex machinery automation grids.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTSXAEY1600\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Premium Automation platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-level analog input module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 high-level inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalogue Input Types (Voltage)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 10 V, 0...10 V, 0...5 V, 1...5 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalogue Input Types (Current)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0...20 mA, 4...20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog-to-Digital Conversion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 bits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Read Cycle Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51 ms for all active channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFast Read Cycle Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 ms + (3 ms x number of channels used)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Measurement Error (25 °C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1% of full scale (+\/- 10 V, 0...10 V, 0...5 V, 1...5 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Measurement Error (0...60 °C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.13% of full scale (+\/- 10 V, 0...10 V, 0...5 V, 1...5 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Measurement Error (25 °C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16% of full scale (0...20 mA, 4...20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Measurement Error (0...60 °C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32% of full scale (0...20 mA, 4...20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Isolation Barriers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1000 Vrms between channels and internal bus\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e1000 Vrms between channels and station ground\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel-to-Channel Topology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommon point architecture (no common mode between channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Overvoltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15...15 V at state 0 (250 kOhm)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e-30...30 V at state 1 (250 kOhm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Overcurrent Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30...30 mA at state 1 (250 kOhm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Connection Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x SUB-D 25-pin high-density connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e270 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Physical Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard single-width slot size\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 lb (0.34 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-Channel High-Density Integration for Compact Enclosures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModern control panels demand massive instrumentation capacities within limited rack space, which often forces engineers to buy multiple low-density input cards. The TSXAEY1600 packs 16 high-level analog inputs into a single standard slot format. This tight spatial layout allows facilities to consolidate high-density telemetry wireways into a smaller chassis footprint, freeing up valuable rail space inside crowded control enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Speed Configurable Read Cycle Engine:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMixing slow, stable environmental variables like tank levels with ultra-fast variables like hydraulic pressure loops usually requires separate specialized hardware. The TSXAEY1600 solves this limitation with its flexible scanning engine. It offers a 51 ms nominal read cycle for standard process loops, alongside a configurable fast-scan mode operating at 3 ms + 3 ms per active channel. This feature allows operators to optimize scanning speeds based on the exact needs of the field instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Voltage\/Current Signal Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-zone industrial systems often feature a mix of 4-20 mA current loops and 0-10 V voltage transmitters, which typically complicates hardware inventory management. This module supports broad signal configuration natively. Software parameters adjust individual channels to accept 0-20 mA, 4-20 mA, +\/-10 V, 0-10 V, 0-5 V, or 1-5 V signals, allowing a single spare card to support diverse field configurations across the plant floor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1000 Vrms Robust Overvoltage Surge Defense:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCross-talk, ground potential shifts, or lightning strikes in outdoor field cable trays can send high-voltage surges back to the main electrical room. The TSXAEY1600 includes heavy-duty galvanic protection, establishing a 1000 Vrms isolation barrier between the input lines, station ground, and the internal backplane bus. Additionally, internal clamping networks provide continuous input overvoltage protection up to +\/-30 V and overcurrent shielding up to +\/-30 mA, stopping destructive surges before they reach the main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Dual SUB-D 25 Connection Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-vibration environments like compressor skids or rolling mills can loosen traditional screw terminals, leading to intermittent signal drops. The TSXAEY1600 utilizes two secure SUB-D 25-pin connector interfaces on the front panel. These mechanical plugs lock directly into place, providing vibration-proof contact points for complex multi-conductor cables while speeding up terminal disconnects during routine maintenance shop checkups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this TSXAEY1600 analog input module a 100% brand new item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this module strictly as a 100% brand new, original factory-sealed unit. It arrives inside its authentic original Schneider Electric corporate carton, complete with undamaged anti-static shielding bags, unmarred faceplate plastics, and matching factory serial number tracking labels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module feature fully isolated channel-to-channel paths?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The TSXAEY1600 utilizes a high-density common point architecture where the 16 channels share an internal reference path, resulting in no common mode between channels. However, the module provides a full 1000 Vrms galvanic isolation barrier between the combined channel array, the internal backplane bus logic, and the station ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does temperature affect the measurement accuracy of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt a standard reference temperature of 25°C, the module achieves an accurate voltage reading within 0.1% of full scale. When operating across the expanded industrial enclosure range from 0°C up to 60°C, the internal precision components limit thermal drift, keeping the total voltage measurement error under 0.13% of full scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I configure different signal types on adjacent channels simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The Modicon Premium configuration software allows you to assign independent input definitions to individual channels. For example, you can set Channel 0 to read a 4-20 mA current loop while configuring Channel 1 to monitor a 0-10 V voltage signal on the same card, providing excellent flexibility for mixed-instrumentation setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52909262471477,"sku":"TSXAEY1600","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TSXAEY1600.png?v=1779356199","url":"https:\/\/www.5gplc.com\/products\/schneider-electric-tsxaey1600-modicon-premium-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}