{"product_id":"schneider-electric-bmxsdi1602-modicon-x80-discrete-input-module","title":"Schneider Electric BMXSDI1602 Modicon X80 Discrete Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric\u003cstrong\u003e BMXSDI1602\u003c\/strong\u003e monitors and captures binary signal states from field sensors within the Modicon X80 PAC platform. This 16-channel discrete input module interface processes status changes from proximity switches, pushbuttons, safety interlocks, and limit switches in demanding industrial applications. By translating physical contact states into clean digital logic frames directly on the X80 backplane, this module drives deterministic automation processes across water treatment systems, food packaging assembly lines, and material handling systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBMXSDI1602\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon X80\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscrete Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDevice Application\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Application\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Not isolated between channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Input Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePositive logic (Sink configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConforms to IEC 60947-5-2 at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Wiring Flexibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports 2-wire or 3-wire sensor connections\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiscrete Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.2 mA at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7,500 Ohm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eParalleling of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Protection Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated reverse polarity protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDeterministic Response Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 ms typical \/ 6 ms maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSensor Power Supply Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19…30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTypical Current Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e256 mA DC \/ 100 mA at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.57 W maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Isolation Barrier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC for 1 minute (Between channels and bus)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMean Time Between Failures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e265,000 Hours (MTBF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Voltage Thresholds\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u0026lt; 14 V DC (Sensor fault detection)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u0026gt; 18 V DC (Sensor OK status)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal Status Signalling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 x Green LED: Module RUN\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e16 x Green LEDs: Individual channel diagnostics\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e1 x Red LED: Module error (ERR)\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e1 x Red LED: Module I\/O fault\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.3 x 1.3 x 3.4 in (134.6 x 32 x 86 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.254 lb (0.115 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Form Factor for Narrow Enclosures:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel builders routinely confront tight space constraints in decentralized control cabinets. The BMXSDI1602 packages 16 discrete input channels into an ultra-slim 1.3-inch (32 mm) housing width. This high-density architecture decreases the required backplane physical footprint, allowing engineers to install extra functionality inside small machine-mount enclosures or crowded terminal boxes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Multi-Point Status Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRapid diagnostic visualization prevents extended troubleshooting delays during unexpected sensor dropouts. The front faceplate of the BMXSDI1602 integrates an array of 16 individual green channel LEDs paired with red module error (ERR) and I\/O fault lights. Maintenance technicians spot broken field circuits, shorted contacts, or physical sensor failures instantly directly on the factory floor without connecting a programming PC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProactive Sensor Voltage Threshold Tracking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFluctuating field power or degraded cabling often causes intermittent control loop signals. This module incorporates automatic internal voltage monitoring circuitry that establishes clear logic barriers. If the input power level sags below 14 V DC, the module triggers a sensor fault flag. Once the field voltage rises past 18 V DC, the system authorizes a sensor OK status, blocking erratic signal transitions during low-power spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1500 V High-Potential Galvanic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-voltage transients, electrical noise from nearby variable frequency drives (VFDs), or direct short circuits on external field wires can destroy downstream logic processors. While the 16 channels share a common internal return path, the module places a robust 1500 V AC galvanic isolation barrier between the input terminal block and the primary X80 backplane bus. This high-potential barrier seals off heavy field noise, keeping the central PAC processor safe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNative Reverse Polarity Wiring Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccelerated project timelines increase the chance of accidental field wiring mistakes during commission operations. The BMXSDI1602 prevents component damage by embedding hardwired reverse polarity protection directly into its input network. If a field wiring crew flips the positive and negative 24 V DC power lines on the terminal block, the safety diodes clip the loop power immediately to prevent hardware destruction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this BMXSDI1602 input module a 100% brand new item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this module exclusively as a 100% brand new, original factory-sealed item. The unit arrives in its original Schneider Electric box, complete with factory bar codes, original anti-static wraps, and pristine terminal contact interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide separate isolation between each of its 16 channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The channels share a common electrical return path on the terminal side (not isolated channel-to-channel). However, the module provides 1500 V AC isolation for 1 minute between the group of input channels and the internal backplane bus to shield the main PLC processing logic from external field spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of sensor cables does the module accept for field deployment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe input circuitry adapts to both 2-wire and 3-wire sensors (such as NPN style or dry contacts wired for positive sink logic) conforming to IEC 60947-5-2. You can wire the field sensors using standard 20-pin removable terminal blocks (screw or spring type), or deploy pre-formed cordsets to reduce panel assembly times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the logic conversion time for an active signal state change?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe BMXSDI1602 features an identical typical and maximum response filtering window of 6 milliseconds. This fixed timing dampens contact bounce from mechanical switches and industrial relays, ensuring clean, debounced digital signals enter the controller application loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52909078675765,"sku":"BMXSDI1602","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BMXSDI1602.png?v=1779351073","url":"https:\/\/www.5gplc.com\/products\/schneider-electric-bmxsdi1602-modicon-x80-discrete-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}