{"product_id":"schneider-electric-bmxcps3020-modicon-x80-high-power-dc-power-supply-module","title":"Schneider Electric BMXCPS3020 Modicon X80 High-Power DC Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eBMXCPS3020\u003c\/strong\u003e drives regulated high-capacity electrical power directly to standard Modicon X80 automation backplanes. Running on an isolated 24 V to 48 V DC primary input network, this module converts wide-range direct current into two highly stabilized secondary rails. It energizes high-density I\/O arrays, advanced communications processors, and main CPUs, serving as the primary electrical backbone for heavy industrial substations, oil and gas telemetry, and transport infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBMXCPS3020\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon X80\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-Capacity Isolated DC Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24...48 V DC isolated (Absolute Limit: 18...62.4 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.65 A at 24 V DC \/ 0.83 A at 48 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current Peak\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A at 24 V DC \/ 60 A at 48 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Power (3.3V Logic)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 W DC (4.5 A) for I\/O module logic power supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Power (24V System)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31.2 W DC (1.3 A) for I\/O module and processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRack Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard X80 racks (Not compatible with BMEXBP..02)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMean Time Between Failures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,600,000 Hours (MTBF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V between primary circuit, secondary circuit, and ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 rating with TC protective treatment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32…140 °F (0…60 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.75 lb (0.34 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide-Range Isolated DC Input Stage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBattery banks and remote DC grids experience major voltage swings. The BMXCPS3020 accommodates an expansive input window from 18 V DC up to 62.4 V DC while maintaining an isolated 1500 V dielectric barrier between the primary inputs and internal backplane logic. This design shields sensitive microprocessors from line surges and floating ground hazards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBoosted Current Output for High-Density Racks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLarge I\/O configurations cause standard power modules to sag. This unit answers that demand by outputting a robust 4.5 A on the 3.3 V DC logic rail (15 W) and 1.3 A on the 24 V DC system rail (31.2 W). This elevated power overhead eliminates the need to install additional supplementary racks or split power zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Secondary Fault Tripping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDownstream wiring errors or shorted field modules can disable a controller. The BMXCPS3020 utilizes independent secondary overvoltage, overload, and short-circuit protection circuits that instantly respond to electrical anomalies, protecting your rack hardware from thermal damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Environmental Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to thrive inside harsh control cabinets, the module limits its maximum power dissipation to 8.5 W, dropping internal cabinet temperatures. Equipped with a TC protective treatment (tropicalization), the card repels moisture and airborne contaminants while resisting 3 gn vibrations and 30 gn mechanical shock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Microbreak Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFluctuating power grids can cause brief drops in line voltage. The internal energy storage of this supply bridges microbreaks up to 1 ms, preventing unexpected PLC resets and data corruption during localized grid disturbances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this BMXCPS3020 power supply a brand new original unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this product strictly as a 100% brand new, original factory unit. It arrives sealed in the authentic Schneider Electric box with all current factory certifications and documentation intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this power supply on both 24V DC and 48V DC battery systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The internal auto-ranging circuitry natively handles isolated inputs from 24 V to 48 V DC (and handles limits from 18 V to 62.4 V DC) without requiring any hardware jumper adjustments or software re-configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support the newer BMEXBP Ethernet backplanes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The BMXCPS3020 works with standard Modicon X80 racks. It is explicitly incompatible with the hybrid Ethernet-enabled backplanes that carry the prefix code \"BMEXBP..02\". Always check your rack model before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the cable distance limitations for wiring the primary power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo avoid excessive line voltage drop, follow the manufacturer limits based on copper wire cross-sections: limit distances to 32.8 feet (10 m) when using 1.5 mm² (0.002 in²) power cables, or extend up to 49.2 feet (15 m) when using 2.5 mm² (0.004 in²) conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52908643483957,"sku":"BMXCPS3020","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BMXCPS3020.png?v=1779343262","url":"https:\/\/www.5gplc.com\/products\/schneider-electric-bmxcps3020-modicon-x80-high-power-dc-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}