{"product_id":"schneider-electric-bmxcps2000-modicon-x80-power-supply-module","title":"Schneider Electric BMXCPS2000 Modicon X80 Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003eBMXCPS2000\u003c\/strong\u003e supplies regulated electrical power to standard Modicon X80 automation racks. This primary AC-driven unit converts mainline utility power into three independent secondary direct-current (DC) rails. It simultaneously energizes the main CPU processor, downstream digital or analog I\/O hardware, and external field sensors, functioning as the foundational power distribution core for discrete manufacturing and infrastructure automation assemblies.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Data\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBMXCPS2000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRange of Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon X80\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100...240 V AC (Absolute Limit: 85...264 V AC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz (Operational Window: 47…63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApparent Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.07 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.61 A at 115 V AC \/ 0.31 A at 240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current Peak\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A at 120 V AC \/ 60 A at 240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Power (3.3V)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.3 W DC (2.5 A) for I\/O module logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Power (24V System)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.8 W DC (0.7 A) for I\/O modules and processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSecondary Power (24V Sensor)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.8 W DC (0.45 A) for dedicated field sensor supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard X80 racks (Not compatible with BMEXBP..02)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMean Time Between Failures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,638,000 Hours (MTBF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;= 100 MOhm between primary circuit, ground, and secondary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.7 lb (0.3 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple-Rail Clean Power Separation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe BMXCPS2000 segregates its secondary output into three dedicated paths: an 8.3 W rail for backplane logic, a 16.8 W rail for module\/processor driving, and an isolated 10.8 W sensor loop. This structure blocks raw field sensor short-circuits or field wiring mistakes from breaching the internal processing bus, preventing total controller corruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Circuit Protection Arrays:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial grid fluctuations damage low-voltage hardware. The module counters this risk through integrated secondary overvoltage, overload, and short-circuit protection circuits. An internal primary fuse provides a final defensive layer against massive grid overcurrent spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExceptional Thermal and Operational Longevity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit achieves an MTBF rating of 4,638,000 hours. The ultra-low internal power dissipation (8.5 W maximum) minimizes heat buildup within sealed electrical cabinets, eliminating the need for forced-air cooling fans and reducing overall thermal stress on surrounding components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManual Cold Restart Overrides:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA dedicated front-panel RESET push-button allows maintenance technicians to initiate a cold restart directly at the rack. This speeds up field commissioning and validation routines by clearing temporary hardware fault lockups without requiring a complete power cycling of the main breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImmediate Dual-LED Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe front face features clear physical status indicators. A green rack voltage LED validates internal backplane status, while a separate green sensor voltage LED confirms active 24 V DC field loop power, shortening visual inspection times during routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this BMXCPS2000 power supply a brand new original unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We supply this module only as a 100% brand new, original factory-packaged item. It ships directly in the authentic manufacturer box with all original factory seals and documentation intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the BMXCPS2000 on any Modicon backplane?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module fits standard Modicon X80 backplanes. However, you must check your rack part number before installation, as this specific power supply does not support Ethernet-enabled hybrid racks beginning with the prefix code \"BMEXBP..02\".\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the primary circuit allow field-level fuse replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The primary circuit utilizes an internal, non-accessible fuse designed to protect the cabinet from catastrophic component failures. If an external fault triggers this fuse, you must swap out the unit. To protect the module, install external circuit breakers or fast-acting fuses upstream on the line supply wire.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wiring terminals do the front connectors provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module separates field connections into two dedicated plug-in block interfaces. One connector provides a pair of alarm relay contacts for remote monitoring, while the second connector groups the 5 line supply wires, protective earth ground, and the 24 V DC sensor output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":52908624052533,"sku":"BMXCPS2000","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/BMXCPS2000.png?v=1779342751","url":"https:\/\/www.5gplc.com\/products\/schneider-electric-bmxcps2000-modicon-x80-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}