{"product_id":"savs20p5-honeywell-control-panel-board","title":"SAVS20P5 Honeywell Control Panel Board","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell SAVS20P5\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSAVS20P5\u003c\/strong\u003e Control Panel Board, operates as a dedicated hardware component for central zone monitoring and alarm loop execution within Honeywell Vista 20P security platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSAVS20P5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ As specified on hardware label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg (1.10 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e467 mm x 290 mm x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Hardwired Zones\u003c\/td\u003e\n\u003ctd\u003e8 hardwired zone inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpandable Capacity\u003c\/td\u003e\n\u003ctd\u003eExpandable up to 15 zones (zone doubling on zones 2-8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Partitioning\u003c\/td\u003e\n\u003ctd\u003eSupports up to 2 independent alarm partitions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eCellular and IP expansion module support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe SAVS20P5 manages zone input circuit state detection through dedicated onboard hardware terminals. Signal conditioning networks provide channel-to-channel isolation across input loops to prevent crosstalk and voltage surges from corrupting loop status evaluation. When integrated into broader process monitoring topologies, remote field instruments interface using 4-20 mA HART loop protocol through isolated gateway interfaces, guaranteeing clean digital signal transmission to central control nodes without ground potential interference across the main enclosure assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the SAVS20P5 achieve zone expansion beyond its 8 baseline hardwired inputs?\u003c\/p\u003e\n\u003cp\u003eA: Zone capacity expands up to 15 zones using hardware zone-doubling resistors across channels 2 through 8 or by integrating compatible bus expansion modules.\u003c\/p\u003e\n\u003cp\u003eQ: What power input specs must be delivered to the main board terminals?\u003c\/p\u003e\n\u003cp\u003eA: The SAVS20P5 main circuit board requires a stable 24 VDC external power supply feed.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the SAVS20P5 control board inside an approved metal enclosure using factory standoff supports to prevent chassis grounding shorts.\u003c\/li\u003e\n\u003cli\u003eDisconnect primary 24 VDC input power and standby battery leads before terminating field zone wiring or installing plug-in communication modules.\u003c\/li\u003e\n\u003cli\u003eInstall specified End-of-Line (EOL) resistors across zone input terminals according to system wiring diagrams to maintain loop fault supervision.\u003c\/li\u003e\n\u003cli\u003eKeep low-voltage DC input lines and zone sensor cabling segregated from high-voltage AC power wiring within the panel enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53208130945333,"sku":"SAVS20P5","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/SAVS20P5.png?v=1784793650","url":"https:\/\/www.5gplc.com\/products\/savs20p5-honeywell-control-panel-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}