{"product_id":"s2bn1d-19030-yokogawa-prosafe-rs-wall-mount-base-unit","title":"S2BN1D-19030 | Yokogawa ProSafe-RS Wall-Mount Base Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa S2BN1D-19030\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a rugged wall-mount base unit for the ProSafe-RS safety instrumented system. This hardware interface facilitates the secure connection between field power supplies and system I\/O modules via AKB cable connector interfaces. Designed for decentralized safety architectures, it manages high-current power distribution while providing extreme environmental protection. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring the safety integrity and electrical isolation required for high-risk industrial processes.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe S2BN1D-19030 utilizes specific suffix logic to define its mechanical and environmental capabilities:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS2BN1D\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: ProSafe-RS I\/O Base Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInstallation Type: Wall mount type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e9\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterface: Cable connector interface (specifically for AKB cables)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtection: Standard type with no explosion protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e3\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEnvironment: ISA Standard G3 coating and wide temperature range (-40 to 70°C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed Code: Always 0\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe S2BN1D-19030 maintains high electrical isolation and power density for field-side operations.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC (+20%\/-10%), up to 11.0 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOver Voltage Protection (OVP):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActivates at 32 V or lower\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage (I\/O to System):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage (Output to Ground):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V AC or higher for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 MΩ or more (at 500 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput to Ground Capacitance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.4 μF or less\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +70°C (Wide range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA Standard G3 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 1.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe S2BN1D-19030 resolves critical deployment challenges in harsh industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile standard base units fail in sub-zero or high-heat conditions, this \"Suffix 3\" variant operates reliably from -40°C to +70°C. This allows for installation in non-climatized field enclosures located in arctic or desert environments without auxiliary heating or cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosive Atmosphere Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ISA Standard G3 conformal coating shields the internal bus and connection points from hydrogen sulfide (\u003cspan class=\"math-inline\"\u003e$H_2S$\u003c\/span\u003e), sulfur dioxide (\u003cspan class=\"math-inline\"\u003e$SO_2$\u003c\/span\u003e), and chlorine. This prevents the \"creeping corrosion\" that typically causes hardware failure in paper mills, refineries, and wastewater treatment plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 1500 V AC withstanding voltage barrier separates the field power loops from the sensitive system backplane. This prevents localized electrical faults or lightning-induced surges from propagating into the central safety controller, maintaining the integrity of the Safety Instrumented Function (SIF).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Distribution Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit handles up to 11.0 A of field power. Integrated Over Voltage Protection (OVP) at 32 V automatically clamps power spikes, safeguarding downstream I\/O modules and field sensors from destructive voltage transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I connect the field power supply to the S2BN1D-19030?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit features dedicated field power supply terminals (EP+, EP-). Use the appropriate power cable to establish a secure link between your 24V DC source and these terminals, ensuring you adhere to the 11.0 A maximum current rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type is required for the system interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"9\" suffix indicates a cable connector interface specifically designed for AKB cables. Ensure you use original Yokogawa AKB signal cables to maintain the required impedance and shielding for ProSafe-RS communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be used in hazardous offshore environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the ISA G3 coating provides excellent salt-air and chemical resistance, the \"0\" suffix indicates the unit does not have explosion protection. For installation in hazardous zones (Class I, Div 2 or ATEX Zones), you must house the unit in a suitably certified explosion-proof or purged enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1.4 kg weight affect wall-mount stability?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1.4 kg weight is relatively light for industrial base units, but we recommend mounting it on a rigid, vibration-dampened surface using all designated mounting points to ensure long-term mechanical stability in high-vibration areas.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52567068606773,"sku":"S2BN1D-19030","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/S2BN1D-19030.jpg?v=1776150476","url":"https:\/\/www.5gplc.com\/products\/s2bn1d-19030-yokogawa-prosafe-rs-wall-mount-base-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}