{"product_id":"psm0004-abb-relion-power-supply-module","title":"PSM0004 ABB Relion Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB PSM0004 2RCA025059A0001R\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePSM0004\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power regulation and internal DC voltage distribution within ABB Relion 615 and 620 series protection relays. The module converts wide-range AC and DC auxiliary supply voltages into filtered, regulated internal power rails, driving relay processing units and output logic circuits under continuous operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePSM0004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Numbers\u003c\/td\u003e\n\u003ctd\u003e2RCA025059A0001R \/ 2RCA024585P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e125 x 100 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC (50\/60 Hz) or 48-250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eOverload, over-voltage, short-circuit protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platforms\u003c\/td\u003e\n\u003ctd\u003eABB Relion 615 \/ 620 Series Relays (REF615, RET615, RED615, REM615)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 25 W (internal conversion dissipation profile)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFinland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Internal Bus Power Delivery\u003c\/h3\u003e\n\u003cp\u003eThe PSM0004 power supply module incorporates deterministic power delivery architecture designed to stabilize processing logic during auxiliary supply transients. Integrated regulation circuits interface directly with the relay backplane bus to deliver ripple-free DC rails to processing hardware. Firmware flash compatibility across the ABB Relion architecture ensures uncorrupted parameter memory retention in non-volatile flash storage during sudden input power interruptions or voltage sags.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What happens if an over-voltage surge occurs on the AC\/DC supply input terminals?\u003c\/p\u003e\n\u003cp\u003eA: The onboard protection circuit clamps transient over-voltage conditions and limits current draw, preventing damage to downstream internal processing boards and relay logic.\u003c\/p\u003e\n\u003cp\u003eQ: Can the PSM0004 power supply board be hot-swapped while the protection relay is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Auxiliary input power must be completely disconnected and isolated from the terminal block prior to extracting or inserting the module to prevent electrical damage to backplane pin headers.\u003c\/p\u003e\n\u003cp\u003eQ: How does the PSM0004 indicate internal power fault conditions to the main CPU module?\u003c\/p\u003e\n\u003cp\u003eA: The module reports internal supply rail drops or short-circuit states through dedicated backplane status lines, triggering a self-supervision watchdog signal on the front display.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following procedures when installing or replacing the power supply unit:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eElectrical Isolation: De-energize all AC and DC auxiliary power sources connected to the relay cabinet terminals. Confirm zero voltage using a calibrated multimeter.\u003c\/li\u003e\n\u003cli\u003eElectrostatic Protection: Wear a grounded anti-static wrist strap before handling the replacement module. Hold the assembly by its plastic edges to avoid touching exposed board traces.\u003c\/li\u003e\n\u003cli\u003eModule Alignment: Align the PSM0004 card edges with the internal guide slots of the Relion relay chassis. Slide the board inward until the backplane multi-pin header fully seats.\u003c\/li\u003e\n\u003cli\u003eTerminal Securing: Tighten the rear panel retaining screws to 0.6 N-m to ensure structural stability and continuous protective earth ground contact.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53433869271349,"sku":"PSM0004 2RCA025059A0001R 2RCA024585P","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PSM00042RCA025059A0001R2RCA024585P.png?v=1788145547","url":"https:\/\/www.5gplc.com\/products\/psm0004-abb-relion-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}