{"product_id":"pr6423-00m-030-con021-eddy-current-sensor-system-emerson-epro","title":"PR6423\/00M-030 \u0026 CON021 Eddy Current Sensor System | Emerson Epro","description":"\u003cp\u003eConfigured for high-speed vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/00M-030\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/00M-030\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e (\u003cstrong\u003eCON021\u003c\/strong\u003e) signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/00M-030 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.35 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -21 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eDC to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CON021 support hot-swap replacement?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CON021 signal converter is designed to support hot-swap replacement within compatible monitoring racks, such as the MMS 6000 and IMR 6000 series, without requiring full system downtime.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP20 rating suitable for direct installation on the turbine skid?\u003c\/p\u003e\n\u003cp\u003eA: No. The IP20 protection class mandates installation within a protective enclosure, control cabinet, or junction box to prevent exposure to moisture, oil mist, or conductive metallic debris.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal wiring using high-quality ferrules on the screw terminals, ensuring the wire gauge does not exceed 1.5 mm².\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround the signal cable shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009109156149,"sku":"CON021+PR6423\/00M-030","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120__1_8570f91c-4247-4ad0-bff0-39b70f9b810a.png?v=1781684651","url":"https:\/\/www.5gplc.com\/products\/pr6423-00m-030-con021-eddy-current-sensor-system-emerson-epro","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}