{"product_id":"pqmii-c-general-electric-pqmii-series-power-quality-meter","title":"PQMII-C | General Electric | PQMII Series Power Quality Meter","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe General Electric\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePQMII-C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision Power Quality Meter within the Multilin product family, engineered for comprehensive monitoring of utility and industrial power systems. This unit provides advanced detection of voltage and frequency anomalies, ensuring the stability of sensitive electrical infrastructure. By utilizing programmable setpoints and high-speed data acquisition, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePQMII-C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical diagnostic tool for energy management and equipment protection.\u003c\/p\u003e\n\u003ch2\u003eVoltage Monitoring Parameters\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePQMII-C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers sophisticated tracking for both over and under-voltage conditions to prevent hardware fatigue and operational failures.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUndervoltage Pickup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.50 to 0.99 x VT (0.01 steps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUndervoltage Dropout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e103% of pickup level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage Pickup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.01 to 1.25 x VT (0.01 steps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage Dropout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e97% of pickup level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUser-programmable for any single phase, any two, or all three phases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime Delay Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 to 600.0 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTiming Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-0\/+1 second\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequency Surveillance and Control\u003c\/h2\u003e\n\u003cp\u003eFor grid stability and generator synchronization, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePQMII-C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitors frequency deviations with high granularity.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20.00 to 70.00 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePickup Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.02 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnderfrequency Dropout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePickup + 0.03 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverfrequency Dropout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePickup - 0.03 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1 to 10.0 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimum 20V applied for accurate sensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnergy Pulse Output and Physical Specs\u003c\/h2\u003e\n\u003cp\u003eThe meter facilitates external integration through programmable pulse outputs for energy consumption tracking.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMonitored Parameters:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePositive\/Negative kWh, Positive\/Negative kvarh, and kVAh\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulse Width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 to 2000 ms (10 ms increments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Interval:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e215 mm x 152 mm x 152 mm (8.5\" x 6\" x 6\")\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.3 kg (5 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications and Integration\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePQMII-C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically deployed in main incoming feeders, motor control centers (MCC), and distributed generation sites. It allows engineers to capture power quality events and automate load shedding or capacitor bank switching based on real-time voltage and frequency data.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PQMII-C monitor specific phases for voltage drops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the unit is fully programmable, allowing the operator to trigger alarms or actions based on a single phase, two phases, or a balanced three-phase monitoring logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum voltage required for frequency monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe meter requires at least 20V applied to the inputs to maintain accurate frequency tracking and pickup performance.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52449820377397,"sku":"PQMII-C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PQMII-C.jpg?v=1773814587","url":"https:\/\/www.5gplc.com\/products\/pqmii-c-general-electric-pqmii-series-power-quality-meter","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}