{"product_id":"plx51-hart-4i-prosoft-hart-4-channel-input-module","title":"PLX51-HART-4I | ProSoft HART 4-Channel Input Module","description":"\u003ch3 data-start=\"160\" data-end=\"189\"\u003e\u003cstrong data-start=\"164\" data-end=\"187\"\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"191\" data-end=\"628\"\u003eThe \u003cstrong data-start=\"195\" data-end=\"212\"\u003ePLX51-HART-4I\u003c\/strong\u003e from ProSoft Technology is a compact DIN-rail mounted HART input module designed to integrate up to four HART-enabled field devices into Rockwell Automation systems. It provides reliable, bi-directional communication, enabling data acquisition and control in multi-vendor industrial environments. This module is engineered for high compatibility, low power consumption, and compact installation in control panels.\u003c\/p\u003e\n\u003ch4 data-start=\"630\" data-end=\"657\"\u003e\u003cstrong data-start=\"635\" data-end=\"655\"\u003eProtocol Support\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"659\" data-end=\"684\"\u003e\u003cstrong data-start=\"659\" data-end=\"682\"\u003eHART Communication:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"685\" data-end=\"972\"\u003e\n\u003cli data-start=\"685\" data-end=\"736\"\u003e\n\u003cp data-start=\"687\" data-end=\"736\"\u003e\u003cstrong data-start=\"687\" data-end=\"700\"\u003eChannels:\u003c\/strong\u003e 4 independent HART input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"737\" data-end=\"835\"\u003e\n\u003cp data-start=\"739\" data-end=\"835\"\u003e\u003cstrong data-start=\"739\" data-end=\"755\"\u003eData Format:\u003c\/strong\u003e Supports standard HART protocol for digital communication over analog signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"836\" data-end=\"904\"\u003e\n\u003cp data-start=\"838\" data-end=\"904\"\u003e\u003cstrong data-start=\"838\" data-end=\"854\"\u003eSignal Type:\u003c\/strong\u003e 4–20 mA analog inputs with HART digital overlay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"905\" data-end=\"972\"\u003e\n\u003cp data-start=\"907\" data-end=\"972\"\u003e\u003cstrong data-start=\"907\" data-end=\"932\"\u003eDevice Compatibility:\u003c\/strong\u003e HART-enabled transmitters and sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"974\" data-end=\"1001\"\u003e\u003cstrong data-start=\"974\" data-end=\"999\"\u003eIntegration Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1002\" data-end=\"1215\"\u003e\n\u003cli data-start=\"1002\" data-end=\"1075\"\u003e\n\u003cp data-start=\"1004\" data-end=\"1075\"\u003e\u003cstrong data-start=\"1004\" data-end=\"1028\"\u003eCommunication Modes:\u003c\/strong\u003e Master\/slave data exchange with HART devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1076\" data-end=\"1152\"\u003e\n\u003cp data-start=\"1078\" data-end=\"1152\"\u003e\u003cstrong data-start=\"1078\" data-end=\"1096\"\u003eConfiguration:\u003c\/strong\u003e Supports HART device polling and parameter read\/write\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1153\" data-end=\"1215\"\u003e\n\u003cp data-start=\"1155\" data-end=\"1215\"\u003e\u003cstrong data-start=\"1155\" data-end=\"1175\"\u003eError Detection:\u003c\/strong\u003e Supports HART standard error checking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1217\" data-end=\"1251\"\u003e\u003cstrong data-start=\"1222\" data-end=\"1249\"\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1252\" data-end=\"1571\"\u003e\n\u003cli data-start=\"1252\" data-end=\"1290\"\u003e\n\u003cp data-start=\"1254\" data-end=\"1290\"\u003e\u003cstrong data-start=\"1254\" data-end=\"1270\"\u003ePart Number:\u003c\/strong\u003e \u003cstrong data-start=\"1271\" data-end=\"1288\"\u003ePLX51-HART-4I\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1291\" data-end=\"1322\"\u003e\n\u003cp data-start=\"1293\" data-end=\"1322\"\u003e\u003cstrong data-start=\"1293\" data-end=\"1310\"\u003ePower Supply:\u003c\/strong\u003e 10–28 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1323\" data-end=\"1376\"\u003e\n\u003cp data-start=\"1325\" data-end=\"1376\"\u003e\u003cstrong data-start=\"1325\" data-end=\"1342\"\u003eCurrent Draw:\u003c\/strong\u003e 70 mA @ 24 VDC, 130 mA @ 10 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1377\" data-end=\"1409\"\u003e\n\u003cp data-start=\"1379\" data-end=\"1409\"\u003e\u003cstrong data-start=\"1379\" data-end=\"1401\"\u003ePower Consumption:\u003c\/strong\u003e 1.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1410\" data-end=\"1449\"\u003e\n\u003cp data-start=\"1412\" data-end=\"1449\"\u003e\u003cstrong data-start=\"1412\" data-end=\"1427\"\u003eDimensions:\u003c\/strong\u003e 101 × 22.5 × 120 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1450\" data-end=\"1472\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1472\"\u003e\u003cstrong data-start=\"1452\" data-end=\"1463\"\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1473\" data-end=\"1544\"\u003e\n\u003cp data-start=\"1475\" data-end=\"1544\"\u003e\u003cstrong data-start=\"1475\" data-end=\"1489\"\u003eEnclosure:\u003c\/strong\u003e Plastic, IP20, suitable for NEMA\/UL open-type panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1545\" data-end=\"1571\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1571\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1560\"\u003eMounting:\u003c\/strong\u003e DIN-rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1573\" data-end=\"1596\"\u003e\u003cstrong data-start=\"1578\" data-end=\"1594\"\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1597\" data-end=\"1846\"\u003eThe \u003cstrong data-start=\"1601\" data-end=\"1618\"\u003ePLX51-HART-4I\u003c\/strong\u003e is ideal for integrating HART field devices into modern PLC systems. It simplifies data collection from sensors such as pressure, temperature, and flow transmitters while maintaining compatibility with legacy control systems.\u003c\/p\u003e\n\u003ch4 data-start=\"1848\" data-end=\"1862\"\u003e\u003cstrong data-start=\"1853\" data-end=\"1860\"\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1864\" data-end=\"1988\"\u003e\u003cstrong data-start=\"1864\" data-end=\"1917\"\u003eQ: How many HART devices can this module support?\u003c\/strong\u003e\u003cbr data-start=\"1917\" data-end=\"1920\"\u003e\u003cstrong data-start=\"1920\" data-end=\"1926\"\u003eA:\u003c\/strong\u003e Supports up to 4 HART-enabled input devices simultaneously.\u003c\/p\u003e\n\u003cp data-start=\"1990\" data-end=\"2092\"\u003e\u003cstrong data-start=\"1990\" data-end=\"2031\"\u003eQ: What is the required power supply?\u003c\/strong\u003e\u003cbr data-start=\"2031\" data-end=\"2034\"\u003e\u003cstrong data-start=\"2034\" data-end=\"2040\"\u003eA:\u003c\/strong\u003e Operates with 10–28 VDC, drawing 70 mA at 24 VDC.\u003c\/p\u003e\n\u003cp data-start=\"2094\" data-end=\"2202\"\u003e\u003cstrong data-start=\"2094\" data-end=\"2135\"\u003eQ: Is this module DIN-rail mountable?\u003c\/strong\u003e\u003cbr data-start=\"2135\" data-end=\"2138\"\u003e\u003cstrong data-start=\"2138\" data-end=\"2144\"\u003eA:\u003c\/strong\u003e Yes, it is designed for standard DIN-rail installation.\u003c\/p\u003e","brand":"PROSOFT","offers":[{"title":"Default Title","offer_id":52395669750069,"sku":"PLX51-HART-4I","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PLX51-HART-4I1.jpg?v=1772521043","url":"https:\/\/www.5gplc.com\/products\/plx51-hart-4i-prosoft-hart-4-channel-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}