{"product_id":"pfea113-65-3bse028144r0065-abb-tension-electronics","title":"PFEA113-65 3BSE028144R0065 ABB Tension Electronics","description":"\u003cp\u003eThe \u003cstrong\u003eABB PFEA113-65 3BSE028144R0065\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePFEA113-65\u003c\/strong\u003e Tension Electronics, operates as a dedicated hardware component for web tension signal processing and multi-channel load cell evaluation within ABB Tension Electronics platforms. The unit processes signals from up to 4 independent load cell units and converts raw force data into analog, digital, and fieldbus outputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePFEA113-65 3BSE028144R0065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN Enclosure Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e+5 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18 to 36 VDC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-channel load unit input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eMultiple analog and digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe PFEA113-65 integrates into centralized PLC logic via its PROFIBUS DP port while maintaining continuous backplane bus communication velocity across system sub-racks. Support for deterministic industrial networks allows real-time cyclical transfer of web tension values. Internal firmware flash compatibility enables parameter configuration and software updates over the communication interface, optimizing network bandwidth and cabinet I\/O density scaling during load cell calibration routines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input power voltage range does the PFEA113-65 accept?\u003c\/p\u003e\n\u003cp\u003eA: The module operates from a nominal 24 VDC external power supply, accepting an allowable voltage window between 18 VDC and 36 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How many load cell units can be connected directly to the PFEA113-65?\u003c\/p\u003e\n\u003cp\u003eA: The electronics unit features multi-channel input circuitry designed to interface with up to 4 separate load cell units simultaneously.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protection rating does the PFEA113-65 housing provide?\u003c\/p\u003e\n\u003cp\u003eA: The module enclosure is built to an IP65 protection rating, shielding internal circuitry against dust ingress and low-pressure water jets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve the following field installation procedures:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eMechanical Mounting: Mount the IP65-rated enclosure securely to the panel surface using proper bolt fasteners to withstand operational vibration.\u003c\/li\u003e\n\u003cli\u003eLoad Cell Cable Shielding: Route individual load cell signal cables through designated cable glands, connecting overall shields to the internal grounding terminal.\u003c\/li\u003e\n\u003cli\u003ePower Termination: Connect the 18-36 VDC power source leads to the terminal block, verifying correct polarity prior to applying power.\u003c\/li\u003e\n\u003cli\u003ePROFIBUS Wiring: Fasten the PROFIBUS DP bus cable using shielded pair conductors, ensuring proper line termination resistors are engaged at network end nodes.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53434347651381,"sku":"PFEA113-65 3BSE028144R0065","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PFEA113-653BSE028144R0065.png?v=1788161877","url":"https:\/\/www.5gplc.com\/products\/pfea113-65-3bse028144r0065-abb-tension-electronics","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}