{"product_id":"p0916nb-foxboro-8-channel-isolated-output-module","title":"P0916NB Foxboro 8-Channel Isolated Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eFoxboro P0916NB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0916NB\u003c\/strong\u003e Field Control Processor, operates as a dedicated hardware component for isolated signal processing and output control execution within Foxboro DCS architectures. It processes control loop signals and manages system memory using 16 MB SDRAM and 32 MB Flash memory while operating from a redundant 24 VDC power interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916NB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg (1.32 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.7 cm x 5.15 cm x 11.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (+32 deg F to +140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8.5 W maximum (non-fault-tolerant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e16 MB SDRAM, 32 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (redundant inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Protocol Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe Foxboro P0916NB incorporates galvanic isolation barriers across its 8 output channels to prevent ground loops from interfering with field instrumentation. Internal signal paths preserve output accuracy when interfacing with 4-20 mA HART loop protocol field positioners, ensuring that control output commands remain unaffected by high common-mode noise or ambient thermal variations at the cold junction compensation (CJC) reference terminals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power redundancy features does the P0916NB module support?\u003c\/p\u003e\n\u003cp\u003eA: The module accepts dual redundant 24 VDC power supply inputs to ensure uninterrupted processor operation in the event of a single power rail failure.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum power consumption of the P0916NB under full load?\u003c\/p\u003e\n\u003cp\u003eA: Maximum power consumption is rated at 8.5 W per module in a non-fault-tolerant operating configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure power supplies to the baseplate mounting position are isolated prior to installing or removing the P0916NB module. Inspect the backplane gold finger connectors and mechanical keying slots for contamination or physical damage before seating the module.\u003c\/p\u003e\n\u003cp\u003eSlide the module into its baseplate slot until the locking latches click into place, securing electrical connection with the 24 VDC redundant power bus. Route field wiring conductors through dedicated cable raceways, maintaining separation between field output lines and high-voltage power cables. Verify that cabinet grounding wires are securely bonded to the main earth ground bar, and ensure all panel conduit entries achieve a minimum of 5 full threads of engagement on NPT fittings.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53398957457717,"sku":"P0916NB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM201P0916AA_4d9ba464-e1d4-4611-a2a1-35fa5ae8e019.jpg?v=1787627581","url":"https:\/\/www.5gplc.com\/products\/p0916nb-foxboro-8-channel-isolated-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}