{"product_id":"p0913kl-foxboro-i-a-series-controller-module","title":"P0913KL Foxboro I\/A Series Controller Module","description":"\u003cp\u003eThe \u003cstrong\u003eFoxboro P0913KL\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0912KL\u003c\/strong\u003e Controller Module, operates as a dedicated hardware component for real-time control logic execution and I\/O point scanning within Foxboro I\/A Series Distributed Control Systems. Powered by an Intel 80C188 processor with 256 KB RAM and 512 KB EEPROM memory, it manages up to 256 I\/O points while executing programs written in ladder logic, instruction list, and structured text.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0913KL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e460 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Foxboro I\/A Series module dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane power bus driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel 80C188\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e256 KB RAM, 512 KB EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 256 I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e0% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Languages\u003c\/td\u003e\n\u003ctd\u003eLadder logic, Instruction list, Structured text\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and FOUNDATION Fieldbus Integration\u003c\/h3\u003e\n\u003cp\u003eThe Foxboro P0913KL incorporates onboard signal conditioning and channel-to-channel galvanic isolation barriers across its backplane interface. This architecture prevents earth potential differentials from degrading analog field telemetry while maintaining noise rejection across FOUNDATION Fieldbus \/ Profibus PA networks and 4-20 mA HART loop protocol instruments linked through system I\/O baseplates.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is application program memory retained during main system power disruptions on the P0913KL?\u003c\/p\u003e\n\u003cp\u003eA: Non-volatile configuration data and control program logic are saved directly to onboard 512 KB EEPROM memory, ensuring full parameter retention without requiring battery backup.\u003c\/p\u003e\n\u003cp\u003eQ: Can the P0913KL module be replaced online without shutting down the entire sub-rack baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports online insertion and removal (hot-swapping) on powered Foxboro I\/A Series baseplates, provided adjacent slot addresses remain locked in logic execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInsert the P0913KL module vertically into its designated baseplate slot, pressing firmly until upper and lower chassis retaining latches click into place. Ensure backplane connectors are clear of dust or foreign objects before seating.\u003c\/p\u003e\n\u003cp\u003eMaintain physical segregation between low-voltage DCS communication channels and high-voltage power distribution lines within the control cabinet. Connect all field cable drain shields to the primary cabinet single-point ground bar. For cabinet conduit penetrations, ensure all threaded NPT fittings achieve a minimum of 5 full threads of engagement to maintain environmental sealing and mechanical grounding integrity.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53394558714165,"sku":"P0913KL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM204P0916AG_d94ed930-d7a2-4849-bd06-dcaa460ed663.png?v=1787562165","url":"https:\/\/www.5gplc.com\/products\/p0913kl-foxboro-i-a-series-controller-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}