{"product_id":"nfcp100-s05-prosafe-rs-safety-control-station-cpu-module-yokogawa","title":"NFCP100-S05 ProSafe-RS Safety Control Station CPU Module | Yokogawa","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFCP100-S05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-performance CPU node for the ProSafe-RS safety instrumented system (SIS). It executes safety logic and manages critical interlocks to protect plant assets and personnel. This module utilizes a dual-redundant architecture to achieve SIL3 safety certifications in demanding industrial applications. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety-critical infrastructure operates with maximum integrity and zero previous runtime.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFCP100\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Control Station CPU Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Safety Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e05\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle 05 revision for enhanced bus stability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit RISC high-speed processor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e256 MB DRAM with ECC (Error Correction Code)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSerial Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232C (2-wire), RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interfaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet, H1 FOUNDATION Fieldbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 60 °C (-4 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 G, 11 ms half-sine\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e230 mm (W) x 130 mm (H) x 60 mm (D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg (3.31 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Integrity through ECC Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NFCP100-S05 utilizes 256 MB of DRAM equipped with Error Correction Code (ECC). This hardware-level feature detects and corrects single-bit memory errors in real-time, preventing the \"silent data corruption\" that often leads to unexpected system trips in safety-critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Multi-Protocol Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CPU integrates Ethernet and H1 FOUNDATION Fieldbus interfaces directly. This allows the module to synchronize data between high-level plant networks and field-level instruments simultaneously, maintaining deterministic timing for safety shutdown functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardened Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for frontline deployment, the unit withstands temperatures up to 60 °C and resists mechanical shocks up to 15 G. These specifications allow for installation in remote instrument enclosures (RIE) located near heavy machinery without requiring specialized climate control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrict EMC Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module meets IEC 61000-4 standards for electromagnetic compatibility. Its internal shielding repels high-frequency interference and electrostatic discharges, ensuring the safety logic remains unaffected by nearby high-voltage switchgear or radio transmissions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NFCP100-S05 support redundant CPU configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ProSafe-RS architecture allows you to pair two NFCP100-S05 modules in a redundant rack. This setup ensures that if one CPU encounters a hardware fault, the stand-by unit assumes control within milliseconds to maintain the safety state of the plant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the Style 05 revision?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Style 05 revision optimizes internal power distribution and enhances signal stability for the 32-bit parallel I\/O interface. This style ensures compatibility with the latest ProSafe-RS bus backplanes while maintaining backward compatibility with legacy S01-S04 racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I handle the grounding for the RS-485 interface?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo prevent ground loops that could disturb safety signals, ensure you ground the cable shield at a single point, typically at the CPU side. The NFCP100-S05 provides dedicated grounding points to comply with IEC safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older NFCP100 module with the S05 version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn most cases, the NFCP100-S05 functions as a direct replacement. However, you must verify your current system software version to ensure it recognizes the Style 05 hardware profile. Contact our technical team to confirm your specific firmware compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777630335285,"sku":"NFCP100-S05","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFCP100-S05.png?v=1776925876","url":"https:\/\/www.5gplc.com\/products\/nfcp100-s05-prosafe-rs-safety-control-station-cpu-module-yokogawa","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}