{"product_id":"mu-tdid52-51304441-200-honeywell-experion-pks-digital-input-module","title":"MU-TDID52 51304441-200 | Honeywell | Experion PKS Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell MU-TDID52 51304441-200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density Digital Input (DI) interface for complex industrial automation environments. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule monitors up to 32 discrete channels, converting field signals into actionable data for the controller. It bridges the gap between field-level sensors and the supervisor system, supporting a massive voltage swing from 24 VDC up to 230 VAC.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMU-TDID52\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51304441-200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC to 230 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 5 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 Vrms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 2 W per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 mm x 60 mm x 40 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.57 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Voltage Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe MU-TDID52 handles a broad input range from 24 VDC to 230 VAC. This versatility allows engineers to consolidate different signal types into a single module type, drastically reducing spare parts inventory and simplifying cabinet design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a response time of less than 5 ms, this module captures high-speed transients and ensures real-time monitoring of critical safety interlocks and process states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 Vrms isolation protects the sensitive backplane electronics from field-side voltage spikes and electrical noise. This robust barrier prevents ground loops and ensures system stability in electrically \"noisy\" industrial sites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 120 mm x 60 mm frame packs 32 channels into a minimal footprint. This design solves the challenge of limited rail space in retrofitted control cabinets without sacrificing I\/O capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegration via Modbus RTU ensures seamless data exchange with various PLCs, HMIs, and SCADA systems, providing flexibility beyond the standard Experion architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support both AC and DC signals simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MU-TDID52 architecture supports a wide range of voltages; however, engineers must wire the module according to the specific common-return requirements of the system to maintain signal integrity across the 32 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting precautions should I take for high-voltage applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure adequate clearance between the module terminals and the cabinet door or adjacent low-voltage components. Given the 230 VAC capability, we recommend strictly following the 1500 Vrms isolation boundaries defined in the Honeywell installation manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a current-version replacement for older Honeywell DI cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 51304441-200 is a standard-current part number. It replaces many legacy digital input assemblies. Verify your current I\/O base compatibility and firmware version to ensure full feature transparency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the authenticity of this MU-TDID52?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original Honeywell packaging. Each module carries the official factory label, serial number, and \"Made in USA\" or authorized country of origin marking for full traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52553470968117,"sku":"MU-TDID52 51304441-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MU-TDID5251304441-200.png?v=1775789802","url":"https:\/\/www.5gplc.com\/products\/mu-tdid52-51304441-200-honeywell-experion-pks-digital-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}